background image

Important Safeguards:

WARNING – When using electrical equipment, basic safety precautions should always be used including the following: 
This product must be installed in accordance with the applicable installation code by a person familiar with the construction  
and operation of the product and the hazards involved.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

P3330

Rev 1/16

SAVE THESE INSTRUCTIONS

Technical Support:  888 / 387-2212   
1300 S Wolf Road, Des Plaines, Illinois, 60018 / 220 Chrysler Drive, Brampton, Ontario L6S 6B6   ©2016 Acuity Brands Lighting, Inc. 

Figure 3

Figure 2

Figure 1

 Disconnect Power 

•  Disconnect Power during installation and maintenance.

 Prepare Luminaire for Mounting

•  Open the wiring compartment by removing the two screws (

A1

) (see Figure 1)

 Install Bolster Plate 

Figure 2 & 3

•  Using the nut and long bolt (1) attach the bolster plate to the pole as illustrated

 Secure Wiring

•  Insert wires through wireway
•  Tether the wires using the cable tie 

 mounted on the bolster plate.

 Mount the Luminaire

•  Hang luminaire on bolt 

 Note the position of the two washers

•  Secure bolt 

 finger tight 

•  Align the bolster plate and attach the short bolt 

•  Tighten bolts 

 and 

 Check Voltage

 

•  Connect leads to proper voltage
•  Attach the appropriate leads to the terminal block mounted on the wiring 

compartment door (

A4

) (See figure 1)

•  Individually cap all unused leads.
•  Close the wiring compartment

Aiming the Optics 

Unless pre-aimed at the factory (options RL or RR), standard fixtures are shipped 
with optics aimed to the front. If a different orientation is needed, the optics can  
be field rotated 90 degrees to the right or to the left. To rotate the optics, follow 
these steps: 

 

 Loosen the screws (

A2

) securing the Driver Housing Cover (

A3

) (see Figure 1) 

and remove cover

 

 Loosen the 4 bolts (

A5

) securing the LED Housing to the Driver Housing.  

After all 4 bolts are removed the LED housing will drop about ¼” allowing  
for rotation.

 

Rotate 90 degrees in any direction

  

Insert back all 4 bolts (

A5

) to secure the LED Housing to the Driver Housing  

and tighten.

 

Close the Driver Housing Cover (

A3

)

Important Safeguards:

WARNING – When using electrical equipment, basic safety precautions should alwats be used including the following:
This product must be installed in accordance with the applicable installation code by a person familiar with the construction 
and operation of the product and the hazards involved.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Mark means lamp contains mercury.  

Follow disposal laws.

See www.lamprecycle.org

Hg

Z-12108

Rev 5    1-1-08

®

SAVE THESE INSTRUCTIONS

Technical Support:  888 / 387-2212   
1300 S Wolf Road, Des Plaines, Illinois, 60017 / 219 Shoemaker Street, Kitchener, Ontario, N2E 3B3 / 220 Chrysler Drive, Brampton, Ontario L6S 6B6

Pole
Drilling
Pattern

3” 

MIN

1-1/2”

3”

Ø 7/16” 

(x2)

Ø 1”

Pole 

Bolster Plate

(This end is 
unthreaded)

Lock washer

Bolster Plate

(This end is
threaded)

Luminaire

Flat washer
Lock washer

Cable Tie

Flat washer

Lock washer

1-3/4” Bolt

2-1/4” Bolt 

Nut

Figure 2

Polycarbonate Guard

• Remove door assembly

from the luminaire

• Locate the four dimples in

the corners of the door and
drill clearance holes for a
#6 screw.

• Assemble and attach the

polycarbonate guard as
illustrated.

Drill 
here

Nut
Lock Washer

Door

Spacer

Flat Washer

Polycarbonate Guard

Flat Washer
Screw

External House Side Shield

Note: External House Side Shield is not suitable for 

Forward Throw distribution - order an Internal 

House Side Shield (Suffix ‘-SH’)

• Remove door assembly from

the luminaire

• Locate the dimples in the door

and drill using the #6 bit
provided.

• Attach the house side shield

using the screws provided.

Drill 
here

Drill 
here

Figure 1

Disconnect Power 

• Disconnect Power during installation and maintenance.

Prepare Luminaire for Mounting

• Open door assembly.
• Remove protective plastic from the reflector sides
• Disconnect Safety Cable from door assembly.
• Swivel door assembly to 

approximately 50˚ and remove.

• For ease of installation, the tray mounted ballast may also be removed.  Hold

tray with one hand while loosening the thumb screw and let hang.  Move past

90˚ to remove.

Install Bolster Plate 

Figure 1 & 2

• Using the nut and long (2-1/4”) bolt 

, attach the bolster plate as illustrated. 

Secure Wiring

• Insert cable through wireway
• Tether the cable using the cable tie 

mounted on the bolster plate.

Mount the Luminaire

• Hang luminaire on bolt 

Note the position of the two washers

• Secure bolt 

finger tight 

• Align the bolster plate and attach the short (1-3/4”) bolt 

• Tighten bolts 

and 

Check Voltage

Luminaires with multi-tap ballasts are factory wired to the highest voltage.  

For other voltages, ensure correct leads are used.

• Connect leads to proper voltage.
• Attach the appropriate leads using approved connectors.
• Individually cap all unused leads.

Orient Optics

• If optical assembly is not

oriented correctly, remove by

loosening four screws to and

rotate as illustrated

Replace Door and Safety Cable

• Align door assembly at approximately 50˚ and re-mount. 
• Re-attach the safety cable

Install Lamp

• Tighten lamp securely. 
• Observe the lamp manufacturers recommendations and restrictions.
• Remove and install compact fluorescent lamps by grasping only the plastic

portion of the lamp.

Close Door Assembly

• Close and secure snap action latch 

LEFT FACING

RIGHT FACING

FORWARD

Important Safeguards:

WARNING – When using electrical equipment, basic safety precautions should alwats be used including the following:
This product must be installed in accordance with the applicable installation code by a person familiar with the construction 
and operation of the product and the hazards involved.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Mark means lamp contains mercury.  

Follow disposal laws.

See www.lamprecycle.org

Hg

Z-12108

Rev 5    1-1-08

®

SAVE THESE INSTRUCTIONS

Technical Support:  888 / 387-2212   
1300 S Wolf Road, Des Plaines, Illinois, 60017 / 219 Shoemaker Street, Kitchener, Ontario, N2E 3B3 / 220 Chrysler Drive, Brampton, Ontario L6S 6B6

Pole
Drilling
Pattern

3” 

MIN

1-1/2”

3”

Ø 7/16” 

(x2)

Ø 1”

Pole 

Bolster Plate

(This end is 
unthreaded)

Lock washer

Bolster Plate

(This end is
threaded)

Luminaire

Flat washer
Lock washer

Cable Tie

Flat washer

Lock washer

1-3/4” Bolt

2-1/4” Bolt 

Nut

Figure 2

Polycarbonate Guard

• Remove door assembly

from the luminaire

• Locate the four dimples in

the corners of the door and
drill clearance holes for a
#6 screw.

• Assemble and attach the

polycarbonate guard as
illustrated.

Drill 
here

Nut
Lock Washer

Door

Spacer

Flat Washer

Polycarbonate Guard

Flat Washer
Screw

External House Side Shield

Note: External House Side Shield is not suitable for 

Forward Throw distribution - order an Internal 

House Side Shield (Suffix ‘-SH’)

• Remove door assembly from

the luminaire

• Locate the dimples in the door

and drill using the #6 bit
provided.

• Attach the house side shield

using the screws provided.

Drill 
here

Drill 
here

Figure 1

Disconnect Power 

• Disconnect Power during installation and maintenance.

Prepare Luminaire for Mounting

• Open door assembly.
• Remove protective plastic from the reflector sides
• Disconnect Safety Cable from door assembly.
• Swivel door assembly to 

approximately 50˚ and remove.

• For ease of installation, the tray mounted ballast may also be removed.  Hold

tray with one hand while loosening the thumb screw and let hang.  Move past

90˚ to remove.

Install Bolster Plate 

Figure 1 & 2

• Using the nut and long (2-1/4”) bolt 

, attach the bolster plate as illustrated. 

Secure Wiring

• Insert cable through wireway
• Tether the cable using the cable tie 

mounted on the bolster plate.

Mount the Luminaire

• Hang luminaire on bolt 

Note the position of the two washers

• Secure bolt 

finger tight 

• Align the bolster plate and attach the short (1-3/4”) bolt 

• Tighten bolts 

and 

Check Voltage

Luminaires with multi-tap ballasts are factory wired to the highest voltage.  

For other voltages, ensure correct leads are used.

• Connect leads to proper voltage.
• Attach the appropriate leads using approved connectors.
• Individually cap all unused leads.

Orient Optics

• If optical assembly is not

oriented correctly, remove by

loosening four screws to and

rotate as illustrated

Replace Door and Safety Cable

• Align door assembly at approximately 50˚ and re-mount. 
• Re-attach the safety cable

Install Lamp

• Tighten lamp securely. 
• Observe the lamp manufacturers recommendations and restrictions.
• Remove and install compact fluorescent lamps by grasping only the plastic

portion of the lamp.

Close Door Assembly

• Close and secure snap action latch 

LEFT FACING

RIGHT FACING

FORWARD

Areos

 LED

Installation Instructions

A2

 

Screws

A5

 

Bolts

A3

 

Cover

A1

 

Screws

A4

 

Wiring Cover

Reviews: