12
12
2. Installation
2. Installation
Installation and wiring must be performed in accordance with the local
Installation and wiring must be performed in accordance with the local
electric code and the following instructions by professional personnel.
electric code and the following instructions by professional personnel.
For safety, please cut off the mains power switch before installation.
For safety, please cut off the mains power switch before installation.
The battery breaker also needs to be cut off if it is a standard model or
The battery breaker also needs to be cut off if it is a standard model or
long backup time model (“S” model) and an external battery cabinet.
long backup time model (“S” model) and an external battery cabinet.
1)
1) Open the
Open the terminal block cover located o
terminal block cover located on the
n the rear panel
rear panel of the
of the
UPS, please refer to the appearance diagram.
UPS, please refer to the appearance diagram.
2)
2) For TN2-6000(S)
For TN2-6000(S) UPS, it is recommen
UPS, it is recommended to
ded to select the
select the UL1015
UL1015
10AWG(6mm
10AWG(6mm
2
2
) wire or other insulated wire which complies with
) wire or other insulated wire which complies with
AWG Standard for the UPS input and output wirings.
AWG Standard for the UPS input and output wirings.
3)
3) For TN2-10000(S)
For TN2-10000(S) UPS, it
UPS, it is recommended
is recommended to select
to select the UL1015
the UL1015
8AWG(10mm
8AWG(10mm
2
2
) wire or other insulated wire which complies with
) wire or other insulated wire which complies with
AWG Standard for the UPS input and output wirings.
AWG Standard for the UPS input and output wirings.
Note:
Note:
Do not use the wall receptacle as the input power source
Do not use the wall receptacle as the input power source
for the UPS, as its rated current is less than the UPS’s maximum
for the UPS, as its rated current is less than the UPS’s maximum
input current. Otherwise the receptacle may be burned and
input current. Otherwise the receptacle may be burned and
destroyed.
destroyed.
4)
4) Connect the
Connect the input and
input and output wires
output wires to the
to the corresponding input
corresponding input
and output terminals according to the following diagram.
and output terminals according to the following diagram.
Note:
Note:
you must make sure that the input and output wires and
you must make sure that the input and output wires and
the input and output terminals are connected tightly.
the input and output terminals are connected tightly.
5)
5) The protective earth
The protective earth ground wire refers to
ground wire refers to the wire connection
the wire connection
between the equipment which consumes electric equipment and
between the equipment which consumes electric equipment and
the ground wire. The wire diameter of protective earth ground
the ground wire. The wire diameter of protective earth ground
wire should be at least as above mentioned for each model and
wire should be at least as above mentioned for each model and
green wire or green wire with yellow ribbon wire is used.
green wire or green wire with yellow ribbon wire is used.
6)
6) After having co
After having completed the installation,
mpleted the installation, make sure the
make sure the wiring is
wiring is
correct.
correct.
7)
7) Please install the lea
Please install the leak current protective breaker a
k current protective breaker at the
t the output
output
power distribution panel of the UPS if necessary.
power distribution panel of the UPS if necessary.