6-2
94MS41 Rev. C1 S/W Ver 2.06
reflectors and glass can substantially reduce light output.
•
Wear the white lightweight fabric gloves that are provided and unpack
the new lamp. Clean the lamp with the alcohol wipe included.
•
Place each end of the new
OLITE
lamp (one end at a time) on the
holders. DO NOT touch the lamp with your hands. Contamination of the
quartz tube of the lamp with skin oils will shorten the life considerably
and may lead to failure.
•
Reconnect the lamp by fully inserting the spade lugs on the connecting
wires under BOTH thumbscrews and tighten. Ensure the wires are
positioned so they do not touch the lamp body or the reflector and cooling
tube.
•
Insert the safety glass into the holders and push against the housing.
Ensure the safety interlock lever is positioned firmly underneath the glass
towards the lamp and not squeezed to the side. Also, ensure the safety
glass is loose enough to allow for heat expansion during an exposure.
The light will not operate unless the safety glass is installed properly.
When the safety glass is properly installed, it will be able to move slightly.
If the safety glass is installed too tight, it may be damaged during use.
Note:
OLITE
Lamps are specifically designed for
OLEC
and undergo
careful testing and preperation before shipment. They carry the
OLEC
Warranty of Satisfaction. Substitutes and copies of lamps
are not approved by
OLEC
, nor do they carry our Warranty.
Use approved
OLEC
replacement parts ONLY!