2-2
94MS42 Rev.B1 S/W Ver 2.06
Connecting the chiller
•
Mount the Flow Meter and Temperature Gauge assembly on a wall in a
horizontal position.
!
Cl
The Flow Meter and Temperature Gauge assembly must
be mounted horizontal or the Flow Meter will not function
properly.
•
Connect the hose from the "Water in from Chiller" to the flow meter.
Temp
guage
Flow
meter
From
chiller
(for 1" ID
hose)
Mount
Assembly
on wall
Overflow
Bucket
Bleed Valve
1/2" NPT
internal taper
thread
Return
to chiller
(1" ID)
•
Connect another hose from the temperature gauge to the "Closed Loop
In".
•
Connect the hose from the "Closed Loop Out" to the "Water out to
Chiller".