Installation Instructions 

 
The weather station consists of a display unit, a combined wind and temperature sensor connected by a six-
core cable; a rain sensor (available separately connected by a four-core cable (only three cores used)) and a 
separate junction box & power supply.  
 

Sensor wiring 

The cables are connected to the individual sensors via the terminal block on the sensor bracket. This can be 
accessed by removing the black cover, where a wiring identification label will be found. 
 

Roof Top Wind/Temperature Sensor 

This unit should be mounted on a mast of 25-50mm, as high and as far away as possible from chimneys, roof 
peaks, buildings, trees and transmitter aerials which may cause wind turbulence or interference. Where 
possible the roof top wind sensor should be mounted at least 2 metres above roof peaks and be secured in 
position with the arm pointing accurately to the north using the compass provided. 
The cable from the roof top wind sensor should be run down to the junction box, making sure it is properly 
secured.  

 

Please note!

 This cable should not be run in close proximity to power or transmitter cables. If it is necessary 

to shorten the cable, please do this when connecting the cable to the display unit. 

 

WARNING:

 Under no circumstances should the wind sensor junction box cover, or the terminal block inside 

be sealed in any way, as it is designed to breathe. 
 

Optional Rainfall Sensor

 - See separate page supplied with sensor. 

 

Junction Box & Power Supply 

This unit allows the wiring from the sensors to be terminated away from the main display cabinet and a single 
multi-core cable to be wired to the display. Five metres (15 ft) of cable are supplied which may be shortened if 
required. 
Increasing its length may cause inaccuracies in the temperature read-outs. 
To avoid water travelling down cables into the junction box it is 

important

 to ensure that the cables drop 

below the junction box, preferably in the form of a 

‘U’ bend. This will allow any water travelling down the 

cables to drip off. 
The plug-in mains power supply is connected to this unit, so care should be taken to site the junction box near 
to a 13A power socket. 

 

Display Console 

The Display Console should be wall mounted by the two key-hole slots in the back panel (220mm centres). 
The cable may be either channelled into the wall or brought out the side of the cabinet by using the cable 
knock-out holes at each side and at the bottom of the cabinet. Please make sure no dust gets into the display 
unit

The display unit is connected to the junction box by an eight-core cable (only seven cores used) fitted to a 
seven way plug. When connecting please 

ensure that the connector is the correct way round.                                                              

 

 

Summary of Contents for AWS200

Page 1: ...User Manual ACCUR8 Classic Weather Station AWS200...

Page 2: ...independently tested by a UKAS accredited laboratory As part of our ongoing policy to improve the design and specification of our products we reserve the right to change any detail given without prior...

Page 3: ...ocation This is particularly dangerous for children The following safety information must be observed at all times Keep packaging materials plastic bags rubber bands etc away from children They can ca...

Page 4: ...0 to 120 F resolution 0 1 C Min Max function available Rainfall Sensor available separately LCD digital read out mm inch selectable Accuracy 5 5ml of water 1mm rainfall resolution 0 01mm Clock 24hr in...

Page 5: ...o circumstances should the wind sensor junction box cover or the terminal block inside be sealed in any way as it is designed to breathe Optional Rainfall Sensor See separate page supplied with sensor...

Page 6: ...5 Installation Diagram...

Page 7: ...ion of the barometer is achieved by adjustment of the screw head on the barometer movement accessible through a hole in the back panel The barometer also uses a second needle which can be used to shad...

Page 8: ...ting the rainfall counters is accomplished by holding button B while on the rainfall screen Hold for 5 seconds to clear the current reading Hold for 10 seconds to clear both current and accumulated re...

Page 9: ...ou suspect the temperature reading to be inaccurate please ensure that the thermometer with which you are comparing is accurate If the temperature reading is only 1 or 2 degrees out then the display c...

Page 10: ...Declaration of Conformity Tempcon Instrumentation Limited declares that the equipment type with item number A8 AWS200 complies with EMC Directive 204 108 EC The full text of the declaration of conform...

Page 11: ...10 This page intentionally left blank...

Page 12: ...11 This page intentionally left blank...

Reviews: