oximeter.
The computer connected with the oximeter for file transfer should conform to IEC
60950-1.
Don’t near active HF surgical equipment and the RF shielded room of an ME
system for magnetic resonance imaging, where the intensity of EM disturbances
is high.
Use of this equipment adjacent to or stacked with other equipment should be
avoided because it could result in improper operation. If such use is necessary,
this equipment and the other equipment should be observed to verify that they
are operating normally.
Use of accessories, transducers and cables other than those specified or
provided by the manufacturer of this equipment could result in increased
electromagnetic emissions or decreased electromagnetic immunity of this
equipment and result in improper operation.”
Portable RF communications equipment (including peripherals such as antenna
cables and external antennas) should be used no closer than 30 cm (12 inches)
to any part of the equipment, including cables specified by the manufacturer.
Otherwise, degradation of the performance of this equipment could result.
The temperature of the enclosure such as the button and LCD display can reach
44.4 degrees . The internal temperature of the shell near the battery can reach
47.1 degrees .So don't touch buttons and screens for more than 10 minutes.
1.1.3CAUTION
For the sake of user’s safety, please use accessories specified in this manual.
For scrapping and disposal of the oximeter and its package, please observe the
local laws and regulations.
The oximeter could be subjected to interference by other equipment even if such
equipment conforms to the requirements of applicable national standard on
emission.
Please properly install or carry the device to avoid damage due to drop, collision,
strong oscillation or other mechanical forces.
This device is used to measure the O
2
content in blood; the following factors could
degrade the measurement performance and accuracy of the oximeter:
1) Strong interference by light (e.g., fluorescent light, dual ruby light, infrared
heater, operating light, direct sunlight) in the application environment will
affect the measurement accuracy.
2) Water vapor and mist in the device.
3) The size of finger measured is out of range.
4) Weak pulse.
5) Venous pulse.
6) The shock, anemia, hypothermia or application of vasoconstrictors may
reduce the arterial blood flow to a non-measurable level.
7) Stain exists in blood vessels.