background image

 

11

 

5  Start-up 

 

Fig. 7: 

Front view

 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

10

 

LED (red) indicates protection mode during warm-up or error on the left output stage channel 

 

11

 

LED (red) indicates protection mode during warm-up or error on the right output stage channel 

 

12

 

LED (blue) indicates ready for operation 

 

13

 

Mains power switch

 

to switch on the AMP III 

 MK 2 

 

5. 1  Description of function  

 
The two red LEDs (10 and 11) signal that the output relay of the output stage channel is open and that means that 
the transmission of a music signal to the connected loudspeaker is interrupted. 
 
The blue LED 12 in the middle signals that the unit is switched on (operational status). 
 
To connect the unit to the mains socket, please press the mains power switch 13 on the front of the unit. To start 
your listing music please check, if the 

MUTE

 switch 9 

on the rear isn’t activated.

 

 
After switching on the mains switch 13 all three LEDs will turn on. After approx. 5 seconds the two red ones will 
extinguish, while the blue LED stays on showing that the unit is running. 
 

5. 2  Operating instructions 

 

 

Switching on: Always 

switch-on the

 

power amplifier last, i.e. after the other devices in your system 

(preamplifier, CD player, etc).  

 

 

Switching off: Always switch-off the power amplifier first and then switch-off the other devices from the 
mains power.  

 

 

When you switch off the unit from the front panel the auxiliary transformer remains connected to the mains 
power. The power consumption is minimal. However, for longer periods of absence always disconnect the 
power amplifier from the mains power by pulling the mains plug from the socket. 

 

 

During a thunderstorm please 

completely

 disconnect the unit from the mains power by pulling out all three 

plugs. 

 

 

Avoid unnecessarily frequent switching the power amplifier on and off. The high amount of switch-on current is 
a heavy burden for the electrical components and so the life of the unit will be shortened by this action. 

 

Summary of Contents for MONO III MK2

Page 1: ...les and correct phase for the loudspeakers 4 5 Connection to mains power 4 6 Replacing damaged mains fuses 5 Start up ____ Page 10 5 1 Description of function 5 2 Operating instructions 6 Looking afte...

Page 2: ...ppliance Protect the mains cable from being walked on or pinched particularly at plugs and the point where they exit from the appliance From time to time check the mains cable and the appliance for da...

Page 3: ...ntion to a procedure practice condition or the like that if not correctly performed or adhered to could result in a damage or destruction to part or the entire component To guarantee a reliable functi...

Page 4: ...ht side Due to these facts and due to its high weight the power amplifier is usually set up in a position near to the floor either between or near the loudspeakers If you cannot set up the power ampli...

Page 5: ...RCA input socket for the preamplifier output signal 6 1 SPEAKERS RIGHT Right loudspeaker output socket pair A 6 2 SPEAKERS RIGHT Right loudspeaker output socket pair B 6 3 Ground contact for shielded...

Page 6: ...of the balanced input XLR Pin 1 Ground shield Pin 2 Non inverting hot 0 Pin 3 Inverting cold 180 These pin assignments comply with the standard adopted by the Audio Engineering Society Refer to the op...

Page 7: ...ery positive effect on important technical parameters e g on distortion characteristics At 5 kHz the damping factor of a power amplifier is relatively linear and has a high value but then for physical...

Page 8: ...each channel the power amplifier has 2 pairs of WBT loudspeaker terminals labelled A and B With this arrangement you can wire your loudspeaker system in a BI WIRING mode If you want to control your l...

Page 9: ...e read chapter 5 2 4 6 Replacing damaged mains fuses Replace fuses only with original types having the same ampere value the same voltage endurance and the same time lag Never use fuses with other amp...

Page 10: ...ns switch 13 all three LEDs will turn on After approx 5 seconds the two red ones will extinguish while the blue LED stays on showing that the unit is running 5 2 Operating instructions Switching on Al...

Page 11: ...cribed together with their corrective action However if it is not possible to remove the malfunction please contact your authorized dealer Malfunction The unit is switched on the blue LED is illuminat...

Page 12: ...e appr 120 watts Loading and screening capacity 110 000 F Zero signal current setting 300 mA Protection circuits clipping HF oscillations and too high DC offset Dimensions H x W x D 350 x 482 x 430 mm...

Page 13: ...ce center responsible for your country For information contact your dealer or distributor in your country In any case please use the original packaging for return transport to the dealer or service ce...