background image

 

7

 

4. 1  Input selection: balanced / unbalanced 

 
The MONO II I

 MK 2 has balanced XLR input sockets

 

5.1 and unbalanced RCA input sockets

 

5.2

To connect a 

preamplifier, please use one of them.

 

 
Fig. 2: INPUT SELECTION

  

 

Please press the button 

INPUT SELECTION

 to use the balanced XLR input 

AUDIO INPUT BALANCED

 or release the button to use the unbalanced 

RCA input 

AUDIO INPUT UNBAL. 

 
You can use either the balanced input or the unbalanced input but not 
at the same time. 

 
 

 
In order to connect this amplifier with a separate preamplifier, e.g. the TUBE PREAMP II from ACCUSTIC ARTS

®

please use interconnect cables with best possible shielding and high quality connectors. This is the only way to 
ensure that the sound quality of the power amplifier is fully exploited.  
 
 

Fig. 3: 

Pin declaration of the balanced input (XLR)

 

 

 

 
Pin 1:

 Ground (shield) 

Pin 2: 

Non-inverting (hot; 0°) 

Pin 3: 

Inverting (cold; 180°) 

 
 

 
These pin assignments comply with the standard adopted by the Audio Engineering Society. Refer to the operating 
manual of your other units to verify that the pin assignments of their connectors correspond to your ACCUSTIC 
ARTS

® 

unit.  

 
 

4. 2  Damping factor linearization  

 

 

Fig. 4: DAMPING CONTROL

 

ON/OFF 

 

The damping factor linearization can improve the performance of your speaker. By pushing 
this button the function is activated (= 

ON

). 

 
 
 
 
 

 

4. 2. 1  General information   

 

The damping factor 

D

 of a power amplifier is determined from the load resistance 

R

L

 (connected loudspeaker, but 

for the measurement assessment 8 Ω resistance) divided by the internal resistance of the amplifier 

R

i

 

Physical equation: D = R

L

 / R

i

 

 

D   : 

damping factor

 

(calculated number) 

R

:  

load resistance (connected loudspeaker, for the measurement assessment 8 Ω resistance) *

 

R

i

  :  

internal resistance of the amplifier (usually measured at 1 kHz) ** 

Summary of Contents for MONO III MK2

Page 1: ...les and correct phase for the loudspeakers 4 5 Connection to mains power 4 6 Replacing damaged mains fuses 5 Start up ____ Page 10 5 1 Description of function 5 2 Operating instructions 6 Looking afte...

Page 2: ...ppliance Protect the mains cable from being walked on or pinched particularly at plugs and the point where they exit from the appliance From time to time check the mains cable and the appliance for da...

Page 3: ...ntion to a procedure practice condition or the like that if not correctly performed or adhered to could result in a damage or destruction to part or the entire component To guarantee a reliable functi...

Page 4: ...ht side Due to these facts and due to its high weight the power amplifier is usually set up in a position near to the floor either between or near the loudspeakers If you cannot set up the power ampli...

Page 5: ...RCA input socket for the preamplifier output signal 6 1 SPEAKERS RIGHT Right loudspeaker output socket pair A 6 2 SPEAKERS RIGHT Right loudspeaker output socket pair B 6 3 Ground contact for shielded...

Page 6: ...of the balanced input XLR Pin 1 Ground shield Pin 2 Non inverting hot 0 Pin 3 Inverting cold 180 These pin assignments comply with the standard adopted by the Audio Engineering Society Refer to the op...

Page 7: ...ery positive effect on important technical parameters e g on distortion characteristics At 5 kHz the damping factor of a power amplifier is relatively linear and has a high value but then for physical...

Page 8: ...each channel the power amplifier has 2 pairs of WBT loudspeaker terminals labelled A and B With this arrangement you can wire your loudspeaker system in a BI WIRING mode If you want to control your l...

Page 9: ...e read chapter 5 2 4 6 Replacing damaged mains fuses Replace fuses only with original types having the same ampere value the same voltage endurance and the same time lag Never use fuses with other amp...

Page 10: ...ns switch 13 all three LEDs will turn on After approx 5 seconds the two red ones will extinguish while the blue LED stays on showing that the unit is running 5 2 Operating instructions Switching on Al...

Page 11: ...cribed together with their corrective action However if it is not possible to remove the malfunction please contact your authorized dealer Malfunction The unit is switched on the blue LED is illuminat...

Page 12: ...e appr 120 watts Loading and screening capacity 110 000 F Zero signal current setting 300 mA Protection circuits clipping HF oscillations and too high DC offset Dimensions H x W x D 350 x 482 x 430 mm...

Page 13: ...ce center responsible for your country For information contact your dealer or distributor in your country In any case please use the original packaging for return transport to the dealer or service ce...