background image

 

9

 

Fig. 5: 

This simplified diagram serves to illustrate damping factor linearization

 

 

  
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 

4. 3  Mute function 

 

Fig. 6: 

Positions of the 

MUTE

 switch

  

 

When the switch 

MUTE 

is pressed, the speaker outputs of the unit are turned off. The blue 

LED is still illuminated, but

 

the speakers get no signal. 

 
Releasing the switch 

MUTE 

activates the speaker outputs. 

 
 
 

The switch 

MUTE

 is designed for very short listening interruptions, to keep the unit on perfect temperature (= 

optimized sound). If you’re not going listen music for a longer time (

e.g. more than 1 hour), please always switch 

off the unit completely by pressing the main power switch 

13

on the front. 

 

 
IMPORTANT! 

 
 
 

 
Please use the MUTE function when connecting speaker cables. It prevents short 
circuits. 

 

4. 4  Loudspeaker cables and correct phase for the loudspeakers 

 
For each channel the power amplifier has 2 pairs of WBT loudspeaker terminals labelled 

and 

B.

 With this 

arrangement you can wire your loudspeaker system in a BI-WIRING mode. If you want to control your 
loudspeakers with only one cable you can either use pair 

A

 or pair 

B

. Both connections are identical and therefore 

have exactly the same characteristics. 
 
Please use only high-quality loudspeaker cables. This is the only way to ensure that the sound quality of the power 
amplifier is fully exploited.  
To connect the cables to the power amplifier or loudspeakers if possible, use high quality terminal ends or banana 
plugs

*)

 and avoid connecting bare litz wires (except: OFC-cables) since these corrode and so restrict the signal flow. 

The terminals on your power amplifier and your loudspeaker are colour coded or marked with a plus (

+

) and minus 

(

-

). Connect the red (

+

) output terminal of your amplifier with the red (

+

) input terminal of your loudspeaker. Proceed 

in the same way with the white or black (

-

) terminals. 

 

Summary of Contents for MONO III MK2

Page 1: ...les and correct phase for the loudspeakers 4 5 Connection to mains power 4 6 Replacing damaged mains fuses 5 Start up ____ Page 10 5 1 Description of function 5 2 Operating instructions 6 Looking afte...

Page 2: ...ppliance Protect the mains cable from being walked on or pinched particularly at plugs and the point where they exit from the appliance From time to time check the mains cable and the appliance for da...

Page 3: ...ntion to a procedure practice condition or the like that if not correctly performed or adhered to could result in a damage or destruction to part or the entire component To guarantee a reliable functi...

Page 4: ...ht side Due to these facts and due to its high weight the power amplifier is usually set up in a position near to the floor either between or near the loudspeakers If you cannot set up the power ampli...

Page 5: ...RCA input socket for the preamplifier output signal 6 1 SPEAKERS RIGHT Right loudspeaker output socket pair A 6 2 SPEAKERS RIGHT Right loudspeaker output socket pair B 6 3 Ground contact for shielded...

Page 6: ...of the balanced input XLR Pin 1 Ground shield Pin 2 Non inverting hot 0 Pin 3 Inverting cold 180 These pin assignments comply with the standard adopted by the Audio Engineering Society Refer to the op...

Page 7: ...ery positive effect on important technical parameters e g on distortion characteristics At 5 kHz the damping factor of a power amplifier is relatively linear and has a high value but then for physical...

Page 8: ...each channel the power amplifier has 2 pairs of WBT loudspeaker terminals labelled A and B With this arrangement you can wire your loudspeaker system in a BI WIRING mode If you want to control your l...

Page 9: ...e read chapter 5 2 4 6 Replacing damaged mains fuses Replace fuses only with original types having the same ampere value the same voltage endurance and the same time lag Never use fuses with other amp...

Page 10: ...ns switch 13 all three LEDs will turn on After approx 5 seconds the two red ones will extinguish while the blue LED stays on showing that the unit is running 5 2 Operating instructions Switching on Al...

Page 11: ...cribed together with their corrective action However if it is not possible to remove the malfunction please contact your authorized dealer Malfunction The unit is switched on the blue LED is illuminat...

Page 12: ...e appr 120 watts Loading and screening capacity 110 000 F Zero signal current setting 300 mA Protection circuits clipping HF oscillations and too high DC offset Dimensions H x W x D 350 x 482 x 430 mm...

Page 13: ...ce center responsible for your country For information contact your dealer or distributor in your country In any case please use the original packaging for return transport to the dealer or service ce...

Reviews: