SP8016-1005
ACCU-STEAM SERVICE MANUAL
PAGE 16
Verify griddle is level front to back and side to side before attempting this procedure.
1.
With the griddle plugged in, set thermostat dial to 200ºF and turn on. If this is a internal thermostat model
2.
you will need to open the control panel to set the thermostat.
Place the weighted temperature probe in the center in the first
3.
1
/
3
of the griddle cooking surface on a
small amount of high temperature cooking oil. Make sure that the probe is between the griddle
weld stud dimples to assure a proper reading.
Allow the griddle to heat to the initial temperature setting.
4.
Increase thermostat setting to 300ºF allow griddle to cycle through two heat cycles.
5.
Place weighted temperature probe and record temperatures according to the chart below
6.
Temperatures shall be within
7.
±5º F of each other across the entire surface.
TESTING
ChAMBER INTEGRITy TEST
Due to the patented design of our griddle it is imperative that the chamber has no leaks as this
allows water to escape and air to move in causing inconsistent temperatures on the cooking surface.
This test will determine if the cooking chamber is functioning properly.
Notes:
Do not use a infrared temperature measuring device as it will not work correctly.
Tools Required:
Level
•
Calibrated Digital Temperature Meter (Such as the Cooper - Atkins EconoTemp
•
Weighted Temperature Probe - ( Such as Cooper/Atkins)
•
DIgital Temperature Meter
&
Weighted Temperature probe