M160_Set_Kurzübersicht_Brief Overview_V1.06_de_en (3)
29 / 31
17 Technical Data
17.1 Mobile terminal
The M160 mobile terminal technical data is contained in the table below.
Housing
ABS
Protection class
IP54
Operating
temperature
-20 °C to 45 °C/-4 °F to 113 °F
Operation down to temperatures of -20 °C in cold storage chambers is
permissible. You should allow the device to run for 20 minutes prior to this.
Condensation on the device must be avoided.
Storage temperature
-20 °C to 70 °C/-4 °F to 158 °F
Relative humidity
5 %
– 90 %, not condensing
Dimensions
200 x 80 x 41 mm (L x W x H)
Weight
Approx. 425 g (M160)
Apporx. 455 g (M160 with UHF-RFID)
Power supply
7.2 V/li-ion change rechargeable battery, 3400 mAh
Display/screen
3.5" TFT colour screen with LED backlight,
240 x 320 pixels, 640 cd/m
2
1 status LED
Touchscreen
Resistive touch, surface hardness at least 3H
Keyboard/buttons
Rapid-entry keyboard with alphanumeric function
15mm button distances, 15 buttons hard shell keyboard, 5 function keys
Barcode scanner
1D scanner integrated in the housing
Processor
Marvell XScale Prozessor PXA 166; 800 MHz
Memory
512 MB Flash, 256 MB RAM,
larger memory available as an option via µSD card
Operating system
Windows Embedded CE 6.0
Interfaces
microSD-Card,
USB 2.0 (Active Sync over DS160),
WLAN radio card according to IEEE 802.11a/b/g/n ,
integrated speaker for system messages
Optional
2D scanner,
Illuminated silicone keyboard,
UHF-RFID: 865 to 868 MHz (EU)
On request
BT-compatible near field communication,
Protective cover,
UHF-RFID: 902 to 928 MHz (Worldwide)
Accessories
Dockingstation DS160