inverter again to work. 

3.

 

After  the  installation  of  the  inverter  is  completed,  be  sure  to  install  the 

terminal cover to prevent the rat from entering the inverter to cause a short 

circuit board and to damage the machine. 

Appendix 1

The specifications of the inverter 

Model 

500

/18V 

Rated capacity 

500

 

Input 

Voltage range of the city 

grid power 

VAC

 

170-240 

Frequency

Hz

 

50±10% 

Output 

Wave 

Pure sine wave 

Frequency

Hz

 

Grid  power  Priority  model

Same  as 

Grid power 

Battery power priority model

12±0.5 

Voltage

VAC

 

Grid  power  Priority  model

Same  as 

Grid power 

Battery  power  priority  model

230±5% 

Shift time 

Typical

6ms

Auto shift

 

Protection 

Overload 

The  inverter  will  be  shut  down 

automatically and warn with light and 

sounds  after  25  seconds  when  get 

overload  by  105-130%,  after  3 

seconds when get overload more than 

150%,  after  1  second  when  get 

overload more than 200%   

Battery 

Type 

  LiFePO4    battery 

Battery protection 

Intelligent 

battery 

management, 

protect  the  battery  from  overcharge 

and over discharge.   

Rated    DC Voltage 

12VDC 

Summary of Contents for 500W/18V

Page 1: ...User Manual Solar Inversion Power Supply System ...

Page 2: ......

Page 3: ...ations 16 Introduction This manual contains the installation operation and use of the device Please read before installing the equipment The operation of the equipment shall be undertaken by professionals in order to ensure the normal operation of the equipment This manual should be kept properly In order to run the equipment it can be used as a reference at any time Basic instructions Solar power...

Page 4: ...e products Solar power inverter combined PV Controller Battery Specific technical parameters are listed in Appendix I II Technical Specifications Ⅰ Structure overview Hybrid inverter structure Characteristic 1 Pure sine wave AC output strong capacity to adapt to the loads 2 Microcomputer CPU control technology excellent performance 3 Full protection function overload short circuit over voltage und...

Page 5: ...ime turn off the equipment and use a dry powder fire extinguisher Using the liquid to extinguish the fire may cause a risk of electric shock 5 Do not place the container filled with liquid on the top of the device so as not to pour it into the device and cause an internal short circuit resulting in electric shock or fire hazard 6 Do not open the device chassis by yourself There is a danger of elec...

Page 6: ...d storage Transportation When the goods are sent they have been thoroughly inspected After receiving the goods please check whether the packaging is damaged or not If there is any damage or missing items you must notify the dealer within 7 days after receiving the goods Unpacking To avoid damage to the equipment special care should be taken when moving the equipment when unpacking the packaging ma...

Page 7: ...violent impact can damage the equipment Ⅳ Panel indication ...

Page 8: ...Ⅵ installation picture ...

Page 9: ...of danger of electric shock 2 Wire preparation first determine the length of the wire determine the location of the installation reduce the length of the wire as much as possible to reduce the power loss 3 First connect the battery pay attention to the positive and negative do ...

Page 10: ...d by qualified technicians with reference to relevant safety standards Environment 1 The equipment must be installed vertically on a horizontal shelf or on the ground Do not stack objects on the equipment 2 The ambient temperature range for equipment operation is 0 C to 40 C and the ideal temperature condition is 15 C to 25 C the air humidity is 0 95 without condensation the battery life is define...

Page 11: ...st be configured Ⅷ equipment operation Read the equipment manual carefully before operating the equipment The equipment should be in charge of the professional to ensure the normal operation of the equipment Danger 1 After the inverter connected to the mains means city power the inverter output may be in a live state means will have electricity even if the inverter is not manually turned on 2 If t...

Page 12: ...ncy Hz Grid power Priority model Same as Grid power Battery power priority model 12 0 5 Voltage VAC Grid power Priority model Same as Grid power Battery power priority model 230 5 Shift time Typical 6ms Auto shift Protection Overload The inverter will be shut down automatically and warn with light and sounds after 25 seconds when get overload by 105 130 after 3 seconds when get overload more than ...

Page 13: ...gram of the inverter panel Refer to page 5 Remarks All technical parameters are subject to change without notice Customer specific products is accepted by our company Appendix 2 Solar controller specification System voltage 18V Solar controller charge current 5A System charge current 5A Solar input voltage 20V Over voltage protect 15V 1 Working temperature 20 to 60 Note Specifications are subject ...

Page 14: ......

Reviews: