Warning 

Our  company  considers  the  personal  safety  of  the  customer  in  the  most 

important  position.  Therefore,  the  customer  or  the  operator  must  read  the 

relevant  steps  in  detail  before  using  the  device  and  strictly  observe  the  usage 

rules  when  using  it.  Even  if  all  the  switches  are  disconnected,  there  is  still  a 

danger of high voltage in the equipment. Any operation that requires the device 

to be moved or opened must be done by an Authorized Technician. 

 

  Transportation and storage

 

 

Transportation 

When  the  goods  are  sent,  they  have  been  thoroughly  inspected.  After 

receiving the goods, please check whether the packaging is damaged or not. 

If there is any damage or missing items, you must notify the dealer within 7 

days after receiving the goods. 

 

Unpacking 

To  avoid  damage  to  the  equipment,  special  care  should  be  taken  when 

moving the equipment; when unpacking the packaging material, ensure that 

it is intact and stored properly for emergency use. 

 

storing 

After the device is received, if it will not be used within seven days, store it 

in a clean, dry, room temperature (0°C to 40°C). 

 

Transportation 

The  equipment  must  be  kept  upright  and  handled  with  care.  Any  fall  or 

Summary of Contents for 500W/18V

Page 1: ...User Manual Solar Inversion Power Supply System ...

Page 2: ......

Page 3: ...ations 16 Introduction This manual contains the installation operation and use of the device Please read before installing the equipment The operation of the equipment shall be undertaken by professionals in order to ensure the normal operation of the equipment This manual should be kept properly In order to run the equipment it can be used as a reference at any time Basic instructions Solar power...

Page 4: ...e products Solar power inverter combined PV Controller Battery Specific technical parameters are listed in Appendix I II Technical Specifications Ⅰ Structure overview Hybrid inverter structure Characteristic 1 Pure sine wave AC output strong capacity to adapt to the loads 2 Microcomputer CPU control technology excellent performance 3 Full protection function overload short circuit over voltage und...

Page 5: ...ime turn off the equipment and use a dry powder fire extinguisher Using the liquid to extinguish the fire may cause a risk of electric shock 5 Do not place the container filled with liquid on the top of the device so as not to pour it into the device and cause an internal short circuit resulting in electric shock or fire hazard 6 Do not open the device chassis by yourself There is a danger of elec...

Page 6: ...d storage Transportation When the goods are sent they have been thoroughly inspected After receiving the goods please check whether the packaging is damaged or not If there is any damage or missing items you must notify the dealer within 7 days after receiving the goods Unpacking To avoid damage to the equipment special care should be taken when moving the equipment when unpacking the packaging ma...

Page 7: ...violent impact can damage the equipment Ⅳ Panel indication ...

Page 8: ...Ⅵ installation picture ...

Page 9: ...of danger of electric shock 2 Wire preparation first determine the length of the wire determine the location of the installation reduce the length of the wire as much as possible to reduce the power loss 3 First connect the battery pay attention to the positive and negative do ...

Page 10: ...d by qualified technicians with reference to relevant safety standards Environment 1 The equipment must be installed vertically on a horizontal shelf or on the ground Do not stack objects on the equipment 2 The ambient temperature range for equipment operation is 0 C to 40 C and the ideal temperature condition is 15 C to 25 C the air humidity is 0 95 without condensation the battery life is define...

Page 11: ...st be configured Ⅷ equipment operation Read the equipment manual carefully before operating the equipment The equipment should be in charge of the professional to ensure the normal operation of the equipment Danger 1 After the inverter connected to the mains means city power the inverter output may be in a live state means will have electricity even if the inverter is not manually turned on 2 If t...

Page 12: ...ncy Hz Grid power Priority model Same as Grid power Battery power priority model 12 0 5 Voltage VAC Grid power Priority model Same as Grid power Battery power priority model 230 5 Shift time Typical 6ms Auto shift Protection Overload The inverter will be shut down automatically and warn with light and sounds after 25 seconds when get overload by 105 130 after 3 seconds when get overload more than ...

Page 13: ...gram of the inverter panel Refer to page 5 Remarks All technical parameters are subject to change without notice Customer specific products is accepted by our company Appendix 2 Solar controller specification System voltage 18V Solar controller charge current 5A System charge current 5A Solar input voltage 20V Over voltage protect 15V 1 Working temperature 20 to 60 Note Specifications are subject ...