ARTICULATED ARM OPENERS USER MANUAL
1.2.2 Dimension Chart
1
1.2 Installation
2x1.5 mm
2
4x0.5 mm
2
TX - 4x0.5 mm
2
RX - 4x0.5 mm
2
2x1.5 mm
2
2x1.5 mm
2
4
4
2
1
5
1. 24V DC blinker with integrated antenna
2. Push Button
3. Photocells
4. 24V DC articulated arm opener
5. TM3 Transmitter
Please comply with the measures shown on the chart for
proper installation. If necessary, please adjust the gate
structure to the best operation.
Before starting the installation, please make sure that the
gate moves smoothly and that :
1) Hinges are properly positioned and greased.
2) No any obstacle in the moving area.
3) No frictions between two leaf gates and on the
ground while moving.
4) Installation reference: to open the gate with 90 degree,
please refer the data table below:
A: Distance between the gate hinge and the wall bracket.
B: Distance between the gate hinge and the motor side.
C: Distance between the gate hinge and the fixing point of the arm.
To open 90 degree.
Inward Opening
Outward Opening
A
C
B
To open 90 degree.
A
C
B
C
50
100
150
200
250
300
unit: mm
A
B
50
625
615
600
585
565
540
100
575
565
550
535
515
/
150
545
540
/
/
/
/
1.2.1 Standard Installation
3
3