ACE088
Page 14 of 21
Rev Date: 9.21.2021
7.
Power Supply Module
Location: The power supply module is an interchangeable unit, and can be removed with ease
from the exterior, rear, portion of the server chassis. Many servers are equipped with redundant
power supplies (at least 2) in some instances there may be more than 2 power supplies
depending on the configuration.
Type and number of fastenings: One (1) latch per module.
Tools required: None.
Procedure: Unplug the power cord from the power supply. Push the release tab on the back of
the power supply module to the side and pull the module straight out.
Selective Treatment/Special Handling Per Annex VII, Directive 2012/19/EU: Any printed circuit
boards within the power supply module must be removed separately from the power supply
module and shall be disposed or recovered in compliance with Directive 2008/98/EC.