In case all the records in the device is uploaded to Server and ‘SEND’ button is 
pressed again, the Instrument will display as ‘No Pending Records’. This message 
also ensures that all the records in device memory is now sent to the Server 

7.

 

To check the records in device, please follow 

Table 5 [Sl.No 6]

 

 

Admin Configuration: 

1.

 

Use the Enter key to input 3 digit password.  

There are 2 different passwords – to enter configuration menu OR to delete the 
device records [Refer 

Table 5

2.

 

Follow 

Table 5

 to change setting in the Configuration Menu if required 

 

Battery Care: 

1.

 

Do not overcharge the battery. Ideal charging time is 120 Minutes if battery is fully 
drained. This is strictly recommended for avoiding any damage to battery. 

2.

 

Charge only if the battery shows 1 blinking bar or if the Instrument is not switching 
ON 

RFID Care: 

1.

 

Do not expose RFIDs in higher temperature than 50 Deg C 

2.

 

Do not bend the RFID tags  

 

Basic Troubleshooting: 

1.

 

Sensor not responding – Blow air gently in both the sensors placed at the top of 
Instrument and check if values are changing. 

2.

 

Network Signal not visible - Check the network or SIM.  

Note: The availability of network in device is subject to transmission from Carrier 
(Airtel, Vodafone, Idea etc..) and the strength in the region. Also check if the 
device is connected to the charging cable and ‘P’ symbol is displayed in the 
battery bar 

3.

 

Records not uploading – Place the Instrument in the area with better network 
connectivity. Switch off & on the Instrument and perform the SEND operation again.   

Page 4 

Summary of Contents for AI-IAQ-SP-IoT

Page 1: ...ry Bar Indicator 4 Bars 4 Bars Full Battery 1 Bar blinking Low Battery 5 Power Indicator Indicates as P when connected to power 6 Temperature Indicator Indicates in Degree Celsius 7 Humidity Indicator Indicates in RH Relative Humidity 8 CO2 Indicator Indicates in PPM parts per million Table 3 Basic operations of Front keys Sl No Button Function 1 Enter 1 Enter in Admin Setting Screen 2 Saving Valu...

Page 2: ...umber 4 SET CO2 OFFSET To set the offset for CO2 Sensor To be used only under senior technician s presence 5 POWER SAVE TIME Time out for Backlit to save power while in battery 6 VIEW RECORDS To view the recorded data present in Device memory 7 DELETE RECORDS To delete all the records in the device memory Separate Password protection 8 EXIT Exit the Admin Setting screen Instructions For Recording ...

Page 3: ...e Instructions For posting Data to Server 1 Ensure sufficient Internet data balance is available in the SIM card before using the Instrument 2 Insert GSM sim card in the SIM slot make sure the SIM is of standard size i e 15 X 25 mm Ensure SIM s corner cut is facing the charger slot Refer Pg 6 for inserting 3 Plug the charging cable to device and check if network signal is displayed in the Instrume...

Page 4: ...s is strictly recommended for avoiding any damage to battery 2 Charge only if the battery shows 1 blinking bar or if the Instrument is not switching ON RFID Care 1 Do not expose RFIDs in higher temperature than 50 Deg C 2 Do not bend the RFID tags Basic Troubleshooting 1 Sensor not responding Blow air gently in both the sensors placed at the top of Instrument and check if values are changing 2 Net...

Page 5: ...Sagar Sharma Technical Head 9989190588 sagar instrukart com within 6 hours 3 L3 Chetan Sachdeva Managing Partner 9394030848 chetan instrukart com within 12 hours Return Address of Instrument In case of any repair Re calibration after 12 months INSTRUKART HOLDINGS Plot no 18 Road no 1 A Czech colony Near Reliance Fresh Sanath Nagar Hyderabad 500018 Phone 040 40262020 7331110506 Note Please mention ...

Page 6: ...comprehensive Instruction Manual video please follow https www youtube com watch v L1JfFXBZV2g CO2 Sensor Temp Humidity Sensor Power Slider Charging In SIM Slot Enter Up Right Exit REC SEND USB Out Antenna Insert this way ...

Reviews: