Configuration> System> Management> SNMPv3 Settings
Engine Boots (2)
Engine Time (34345)
SNMP Message Size ... (1500)
1. Users >
2. Targets & Notify >
3. SNMPv1/v3 Mapping >
4. SNMPv3 Factory Defaults
5. Summary User Table []
6. Summary Target Table []
>
Please select item <1 to 6>
ESC-prev.menu; !-main menu; &-exit
Figure
4-18. SNMPv3 Settings Menu
Table
4-16. SNMPv3 General Information and Options
Parameter Description
Possible
Values
Engine boots
Number of times that the SNMP engine has re-
initialized since its identification was configured
last (read-only)
1–2147483647
(1–7FFFHHHFH)
Default: 0
Engine time
Number of seconds since the last SNMP engine
boot (read-only)
1–2147483647
Default: 0
SNMP message
size
The maximum length of an SNMP message (in
octets) that the SNMP engine can send, receive
and process (read-only)
484–2147483647
Default: 1500
Users
Add SNMPv3 users or edit existing users
See
Targets & Notify
Define the SNMPv3 network management
stations to which
ACE-3105, ACE-3205 should send trap
notifications
See
SNMPv1/v3 Mapping Option which allows SNMPv1 and SNMPv2 to be
mapped (work alongside) SNMPv3
See
SNMPv3 Factory
Defaults
Selecting this option resets the SNMPv3
configuration and reinstates the factory default
settings
Summary User Table View the list of current users and their details
See
Summary Target
Table
View the list of current targets and their details
See