Chapter
4 Configuration
Installation and Operation Manual
4-96
Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
Signaling
protocol
Access the LDP options
See
below
Tunnel LSP
Access the Tunnel LSP options
See
Configuring the LDP Signaling Protocol
ACE-3105, ACE-3205 uses the MPLS label distribution protocol (LDP) to
automatically assign and distribute pseudowires and tunnel labels between MPLS
peers.
³
To access the LDP parameters:
1.
From the MPLS menu (see
), select Signaling Protocol.
The Signaling Protocol menu is displayed.
2.
Select LDP.
The LDP menu is displayed.
ACE-3205 - RAD Data Communications
Configuration> Applications> MPLS> Signaling protocol> LDP
1. LDP ID ... (0.0.0.0)
2. Mode ... (Disable)
3. Hello timer (sec) )[1-65534] ... (45)
4. Keep alive timer (sec)[1-65534] ... (40)
5. Interface >
6. Targeted peers >
>
Please select item <1 to 6>
ESC-previous menu; !-main menu; &-exit
Figure
4-68. LDP Menu