Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-46
Monitoring Performance
ACE-3105, ACE-3205 Ver. 5.2
ACE-3205 – RAD Data Communications
Monitoring> Applications> ATM> CES XC> OAM statistics
RX AIS ... (0)
RX RDI ... (0)
TX RDI ... (0)
LOC ... (0)
FM SES ... (0)
FM UAS ... (0)
Time elapsed ... (500)
Valid intervals ... (1)
1. Interval [0-24] ... (0)
2. XC ID ... (1)
>
Please select item <1 to 2>
ESC-prev. menu; !-main menu; &-exit
Figure
6-38. CES OAM Statistics
Table
6-33. CES OAM Statistics Parameters
Parameter Description
Possible
Values
RX AIS
Number of seconds during which AIS cells were
received
Numerical
RX RDI
Number of seconds during which RDI cells were
received
Numerical
TX RDI
Number of seconds during which RDI cells were
transmitted
Numerical
LOC
Number of seconds during which the LOS (loss of
continuity) state was declared. Valid only when CC is
activated.
Numerical
FM SES
Number of seconds during which AIS cells were
received or a LOC state was declared
Numerical
FM UAS
After 10 consecutive seconds of FM SES state, the
FM UAS state is declared. Vice versa, the FM UAS
state is deactivated after 10 consecutive seconds
without the FM SES state. This parameter therefore
counts the number of times on which FM UAS was
declared.
Numerical
Time Elapsed /
Start Time
Time Elapsed is the period in seconds since the
beginning of the current interval.
Start Time is for intervals 1–24.
0–899
Valid intervals
The number of intervals that are saved
0–24