Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-61
Table
6-48. Pseudowire Status Parameters
Parameter Description
Possible
Values
Top row
The top row displays:
•
Ethernet port type and port number
•
PW number (can be changed below)
•
VPI/VCI of the PW connection.
PW type
Type of the pseudowire connection
ATM VP 1 to 1
ATM VC 1 to 1
ATM VP N to 1
ATM VC N to 1
AAL5-SDU
SAToP
Basic CES PSN
Operational
status
Indicates the current status of the
PW connection:
•
Up – the connection is up and running
•
Down – the connection is down
•
Not present – a configuration is
missing
•
Lower layer down – the underlying
layer (MAC, tunnel) is down
Up
Down
Not present
Lower layer down
Local status
The status of the pseudowire at the local
side
Note: There is no Local Status if PW Type
is AAL5-SDU.
Forwarding
Local Faults
Local status faults
The faults at the local side of the
pseudowire connection
Note: This field may display one or more
faults.
No faults
NotFwding – PW
cannot send packets
AcRx – Errors on the
receiving channel of
the attachment circuit
AcTx - Errors on the
transmitting channel
of the attachment
circuit
PsnRx - Errors on the
receiving channel of
the pseudowire
towards the PSN.
PsnTx - Errors on the
transmitting channel
of the pseudowire
towards the PSN.