Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Handling Alarms and Traps
6-71
Table
6-56. BFD (PW Connectivity) Events List
No.
Event String
Status
PW #
1.
BFD Up
No diagnostic
PW #n
2.
BFD Down
No diagnostic
PW #n
3.
BFD Down
Control detection time expired
PW #n
4.
BFD Down
Neighbor signaled session down
PW #n
Table
6-57. PW Events List
No.
Event String
Status
PW #
1.
PW Up
No diagnostic
PW #n
2.
PW Down
No diagnostic
PW #n
Table
6-58. TDM PW Alarm Forwarding Events List
No.
Event String
Status
PW #
1.
RX L|M='100'
Start/End
PW #n
2.
RX R=L
Start/End
PW #n
3.
Underrun
Start/End
PW
#n
Table
6-59. LDP Events List
No. Event
String Status
ID
1.
LDP Session Up
Peer LDP
#
2.
LDP Session Down Peer LDP
#
6.3
Handling Alarms and Traps
ACE-3105, ACE-3205 includes a configurable mechanism of detecting and
reporting alarms. Upon the occurrence an alarm, ACE-3105, ACE-3205 sends or
does not send an alarm trap to the network manager location, depending on a
pre-configured activation or masking of that specific alarm trap.
Even though masked traps are not sent, all alarms are recorded in the system
event log upon their occurrence.