Installation and Operation Manual
Chapter
4 Configuration
ACE-3105, ACE-3205 Ver. 5.2
Configuring for Operation 4-71
Configuring OAM Descriptors
You can define up to 256 OAM descriptors, which can be set to work in
End-to-End, Segment or Intermediate mode. Each descriptor's continuity check
direction can be set accordingly.
³
To access the OAM descriptors configuration menu:
•
From the OAM menu, select OAM descriptor (OD).
The OAM Descriptor menu is displayed.
ACE-3205 – RAD Data Communications
Configuration> Applications> ATM> OAM> OAM descriptor(OD)
1. OAM descriptor number ... (1)
2. OAM mode > (Segment)
3. CC Direction > (None)
4. Loopback operation > (Off)
5. Loopback address ... (FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF)
>
Please select item <1 to 5>
ESC-previous menu; !-main menu; &-exit
Figure
4-53. OAM Descriptors Menu
Table
4-46. OAM Descriptor Parameters
Parameter Description
Possible
Values
OAM descriptor
number
The identifying number of the specific OAM
descriptor which details are displayed. Use the
Forward (F) and Backward (B) keys to browse
through the OAM descriptors.
Note:
•
1 and 2 are default OAM descriptors and cannot
be deleted or modified.
•
OAM descriptor cannot be changed while being
used by connections
.
1–256
OAM mode
The OAM mode of the descriptor
End-to-End
Segment
Intermediate
CC direction
OAM continuity check function mode.
Note: Not valid in Intermediate OAM mode.
None
Source
Sink
Both
Default: None
Loopback operation
OAM loopback function mode.
Note: Not valid in Intermediate OAM mode.
On
Off