Chapter
4 Configuration
Installation and Operation Manual
4-72
Configuring for Operation
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
Loopback address
The OAM loopback address that is transmitted on
each OAM loopback cell.
The destination address parameter is visible only
if the loopback operation is set to On.
00 – FF
°
16 (Hex)
Default: FF
°
16*
* 16 times FF (Hex)
An OAM descriptor cannot be modified when it is used by connections.
Configuring IMA Groups
ACE-3105, ACE-3205 allows the creation of IMA (Inverse Multiplexing over ATM)
groups for E1/T1 or SHDSL ports. IMA groups are created and configured via the
IMA menu.
³
To access the IMA configuration menu:
•
From the ATM menu (see
), select IMA.
The IMA menu is displayed.
ACE-3205 – RAD Data Communications
Configuration> Applications> ATM> IMA
1. Group number ... (1)
2. Item ... (1)
3. Min RX\TX links ... (1)
4. Group ID ... (0)
5. TX frame length (cells) ... (128)
6. Max differential delay (ms) ... (25)
7. Blocking > (Unblock)
8. IMA version > (1.1)
9. Common TX clock source > (System)
10. OAM cell generation > (Disable)
11. Links in group > (1,3,5-7)
12. Restart group
>
Please select item <1 to 11>
ESC-previous menu; !-main menu; &-exit
Figure
4-54. IMA Menu
Table
4-47. IMA Menu Parameters
Parameter Description
Possible
Values
Group number
The IMA group's starting port number. Use
the Forward (F) and Backward (B) keys to
browse through the existing groups, or enter
the number of a new group that you want to
define.
1–4/8/16
Note