Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-4
Monitoring Performance
ACE-3105, ACE-3205 Ver. 5.2
Table
6-3. Active Alarms Menu Parameters
Parameter Description
Possible
Values
Alarm type/name
The active alarm type/name is
listed on the left column of the
screen.
System alarms, physical layer
alarms, ATM layer alarms (LOS,
LOC, PS, etc.)
Alarm parameters
The alarm parameters appear in
the corresponding row
•
Port type, port number for
physical layer alarms.
•
Port type, port number,
IMA group number, VPI and
VCI for ATM layer alarms.
•
Power supply / fan status
For more information about alarm traps, see
.
Viewing the Event Log
The event log displays information regarding all events that occurred up to this
point.
³
To view the event log:
1.
From the System menu (see
), select Event Log.
The Event Log menu is displayed.
ACE-3205 – RAD Data Communications
Monitoring> System> Event log
1. View event log [ ]
2. Clear event log
>
Please select item <1 to 2>
ESC-previous menu; !-main menu; &-exit
Figure
6-4. Event Log Menu
2.
From the Event Log menu, select View Event Log.
The View Event Log screen appears and displays information regarding all
recorded events.
ACE-3205 – RAD Data Communications
Monitoring> System> Event Log> View Event Log
2004-03-04 5:38:50 LOS Start T1 Port 1
>
ESC-previous menu; !-main menu; &-exit
Figure
6-5. View Event Log
Note