Chapter
6 Monitoring and Diagnostics
Installation and Operation Manual
6-42
Monitoring Performance
ACE-3105, ACE-3205 Ver. 5.2
Parameter Description
Possible
Values
FM SES
The time in seconds during which AIS cells where
received or LOC state was declared
Numerical
FM UAS
Activated as a result of 10 consecutive SES’s, and
deactivated as a result of 10 consecutive seconds
without SES.
Numerical
Time Elapsed /
Start Time
The period in seconds since the beginning of the
current interval.
Start Time is for intervals 1–24.
0–899
Valid intervals
The number of intervals that are saved
0–24
Interval number
The interval number to be displayed
0–last interval, max 24
0 if no interval
Default: 0
XC ID
ID of the XC for which the statistics above are
displayed
XC number
Displaying the ATM XC OAM Loopback Statistics
³
To view the XC OAM loopback statistics:
•
From the ATM XC monitoring menu (see
), select OAM Loopback
Statistics.
explains the displayed OAM loopback statistics parameters and
other display options that are available.
ACE-3205 – RAD Data Communications
Monitoring> Applications> ATM> ATM XC> OAM Loopback statistics
Average delay (usec) ... (0) Average delay (usec) ... (0)
Minimum delay (usec) ... (0) Minimum delay (usec) ... (0)
Maximum delay (usec) ... (0) Maximum delay (usec) ... (0)
CDV ... (0) CDV ... (0)
Errored sessions ... (0) Errored sessions ... (0)
Time elapsed ... (500)
Valid intervals ... (1)
1. Interval [0-24] ... (0)
2. XC ID ... (1)
>
Please select item <1 to 2>
ESC-Previous menu; !-Main menu; &-exit
Figure