Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Monitoring Performance
6-47
Parameter Description
Possible
Values
Interval number
The interval number to be displayed
0–last interval, max 24
0 if no interval
Default: 0
XC ID
ID of the XC for which the statistics above are
displayed
XC number
³
To view the VCL OAM Loopback statistics:
•
From the CES Connection menu, select OAM Loopback Statistics.
explains the displayed user statistics parameters and other
display options that are available.
ACE-3205 – RAD Data Communications
Monitoring> Applications> ATM> CES XC> OAM Loopback statistics
Average delay (usec) ... (0)
Minimum delay (usec) ... (0)
Maximum delay (usec) ... (0)
CDV ... (0)
Errored sessions ... (0)
Time elapsed ... (500)
Valid intervals ... (1)
1. Interval [0-24] ... (0)
2. XC ID ... (1)
>
Please select item <1 to 2>
ESC-Previous menu; !-Main menu; &-exit
Figure
6-39. CES OAM Loopback Statistics
Table
6-34. CES OAM Loopback Statistics Parameters
Parameter Description
Possible
Values
Average delay
The average delay required for the OAM cells
roundtrip, in microseconds.
Numerical
Minimum delay
The minimum delay that is allowed for the OAM
cells roundtrip, in microseconds.
Numerical
Maximum delay
The maximum delay that is allowed for the OAM
cells roundtrip, in microseconds.
Numerical