Installation and Operation Manual
Chapter
6 Monitoring and Diagnostics
ACE-3105, ACE-3205 Ver. 5.2
Testing the Unit
6-77
Table
6-63. Physical Loopback Diagnostics Menu Parameters
Parameter Description
Possible
Values
Port type
Type of the diagnosed port
E1/T1
Port number
Number of the diagnosed port
1–4/8/16
Loopback
operation
The loopback operation mode:
•
Disable – The loopback mode is
disabled.
•
External – The received signal for this
interface is looped back out through
the corresponding transmitter in the
return direction.
•
Internal – The signal that is about to be
transmitted is connected to the
associated incoming receiver.
Disable
External
Internal
Default: Disable
Performing Application Tests
Application-level tests are performed at the following categories:
•
•
Performing IP Connectivity Tests
³
To access the application diagnostics menu:
•
From the Applications menu (see
), select Applications.
The application diagnostic options are displayed.
ACE-3205 – RAD Data Communications
Diagnostics> Applications>
1. ATM >
2. IP >
3. LDP >
>
Please select item <1 to 2>
ESC-previous menu; !-main menu; &-exit
Figure
6-65. Application Diagnostics Options