ACE-3105, ACE-3205 Ver. 5.2
Site Requirements and Prerequisites
2-1
Chapter
2
Installation and Setup
This chapter describes the physical installation and setup of ACE-3105, ACE-3205,
and includes the following topics:
•
Site Requirements and Prerequisites
•
•
•
•
Connecting to DSL Network Equipment
•
Connecting to Packet-Switched Networks
•
Connecting to a Control Terminal
•
.
•
No internal settings, adjustment, maintenance and repairs should be
performed by either the operator or the user. Such activities must be
performed only by skilled personnel who are aware of the hazards involved.
Always observe standard safety precautions during installation, operation and
maintenance of this product.
•
A grounding cable must be connected to the dedicated grounding screw,
located next to the power supply outlet(s) at the front. The other end of the
cable must be connected to a proper grounding (Earth) point.
2.1
Site Requirements and Prerequisites
AC-powered ACE-3105, ACE-3205 units should be installed within 1.5 meters
(5 feet) of an easily accessible grounded AC outlet capable of furnishing the
required supply voltage, in the range of 100 to 240 VAC, 50 or 60 Hz.
Allow at least 15 cm of frontal clearance for operator access. For cable
connections and continuous product operation, allow at least 15 cm of frontal
clearance and at least 15 cm at the rear of the unit.
ACE-3105 has one internal fan (the industrially hardened version) and ACE-3205
has two internal fans. The normal ambient* operating temperature is 0
°
–50
°
C
(32
°
–122
°
F), at a relative humidity of up to 90%, non-condensing.
Warning