background image

Balance line

Balance line

Dedicated

strainer

Outlet

Inlet

Type A

Type B

USER GUIDE

Be sure to read the user guide before installation 

and use.

The product warranty is included in the user guide.

www.acetrap.com

1. Thank you very much for purchasing this product.
2. Please read this manual thoroughly before using the product and keep it in 
    an easy-to-find place.
3. In order to fully demonstrate the performance of this product, please observe 
   the operation method and precautions for use.

-This manual is intended to protect users' safety and prevent property damage.-

Be sure to read it and use it correctly

youtube search : acetrap

https://youtu.be/VSvrPt3-zWM

Installation_

receiver tank, etc.

Inlet connection

_

 

Among the two inlets on the side, 

according to the level of the inlet, connect using a ball valve 

and union as shown in the figure. The connecting inlet 

should have a horizontal or downward sloping flow and 

should not be angled upwards, such as on a camel, to 

connect to the trap. This is because condensate does not 

naturally flow into the trap.

Balance line

_

 

Use a pneumatic hose or metal tube 

(6-8 mm) to connect a balance line with the same pressure 

as the inlet pressure. The balance line is usually taken from 

a level above the level where the condensate collects 

(mainly from the gauge if it is a tank).

AIR

for compressed air system

ATM C2000-08

ACETRAP

®

ACE Co.,Ltd

Receive Tank

Filter

Field end

Dryer

If the balance line is not 

installed, condensate does 

not flow into the trap due to 

the air pocket

1

 phenomenon.  

It doesn't work.

Caution

Caution

Caution

Caution

If there is strong vibration (reciprocating 

compressor) in the inlet line, use a flexible 

hose, etc. to block the vibration.

(Air pocket

1

 Tip :

https://acetrap.com/eng/acetrap/installation.html

Type C

Always install traps 

horizontally. 

Do not install 

upside down.

(Air vent

2

 installation Tip : 

https://acetrap.com/eng/acetrap/installation.html

To facilitate the inflow of condensate in places where it is 

difficult to connect the balance line, install Air Vent

2

.  

In this case, use the lower of the two on the side of the 

housing for the inlet, and install the air vent on the side of 

the balance line on the top of the housing. Air vents are 

optional and must be ordered separately.

This installation method is used when 

the inlet line goes from top to bottom 

without bending. In this case, the 

balance line is unnecessary, and you 

can connect it directly to the top of 

the housing entrance as shown in the 

figure.

Installation where the inlet descends 

from above_ 

Filters, field lines, etc.

Installation in places where it is difficult to 

install a balance line_ 

Dryer, etc.

Inlet

Air vent

Dedicated 

strainer

        The air vent should 

        always be slightly 

      opened, and it should be 

checked frequently. 

(If it is not opened, condensate will not enter the trap and 

it will not work).