Acetrap15N
•
Acetrap15NS
Model
IN₁
Acetrap15N
Acetrap15H
Acetrap15NS
Acetrap15L
W
L
L₁
L₁
H
H
₁
H
₃
H
₂
W
L
H
H
₁
H
₃
H
₂
IN
OUT
Pilot Air
Weight
(kg)
L
L
1
H
H
1
H
2
H
3
106 19 78 14
W
82
95
177 60
M5
1.1
1.2
1/2” 3/8”
pilot air
pilot air
OUT
OUT
IN₂
IN₃
IN₁
IN₂
IN₃
Caution
Caution
Since the heater is hot during operation,
there is a risk of burns if touched with bare
Option
If it is installed in an outdoor service
tank or in the shade of a building,
the condensate may freeze in winter,
causing damage to the ball float inside
and, in severe cases, damage to the
housing. At this time, use a dedicated
heater to prevent the condensate from freezing. Also, if
freezing is expected on the inlet pipe coming into the trap,
it should be kept warm by wrapping it with an insulating
material or a heating wire. Use the lower of the two side
inlets of the housing for the heater.
Power specifications are 220 Volts or 110 Volts.
If foreign matter larger than the
nozzle diameter
3
of the ace trap occurs,
connect a dedicated strainer to the front
of the trap. To clean the strainer, close
the inlet and balance air and fully open
the ball valve connected to the strainer.
In this state, slightly open the balance air to clean it
thoroughly. It can be cleaned easily without disassembly
and assembly, and since the discharged air has pressure,
connect it to the exhaust pipe of the trap, taking care not
to splash foreign objects on people and the floor of the site.
(Note: Ball valve nozzle diameter
3
;
Acetrap 15 is 5Ø, Acetrap 20 is 7Ø)
①
Heater
②
Dedicated strainer
Using an installation bracket can
provide a more stable installation.
To install the bracket, unscrew the two
wrench bolts under the housing plate
and connect the bracket first, and then
fix it by anchor bolts into the floor.
③
Mounting bracket
Do not use two tanks with
different pressures for one
trap. Because the two tanks
have a differential pressure,
condensate moves from the
high pressure tank to the
low pressure tank, and the
trap does not function
properly.
Maintenance
(Pilot line separate piping installation
4
Tip :
https://acetrap.com/eng/acetrap/feature.html
Parts list
The air vent is a function that simply
blows the air out of the container to the
atmosphere. At this time, the pressure in
the inner vessel is lowered, and it serves
to attract condensate into the vessel.
There are several shapes, and types are
1/4” and 1/2”.
④
Air vent
⑤
NPT thread
Warning
Warning
The product is always under pressure.
Be sure to work after removing the pressure.
Problem
Causes
Solutions
No
discharge
Keep
leaking
No condensate inflow.
Damage to parts due to
freezing.
Air chamber damage.
Blockage of inlet or outlet
lines.
Inlet piping cleaning and replacement.
Replace the air chamber set.
Pilot line foreign object
interference.
Consumables are worn out.
Replacement of related consumables.
Pilot line separate piping
4
.
Replace all damaged parts.
Check that the balance line is properly
installed.
Copyright © ACE
Plastic outlet sets are standard, aluminum metal is optional.
Replacement parts available for supply:
(M) maintenance parts, (R) Repair parts
①
①
②
③
④
⑥
⑦
⑧
⑨
⑩
⑪
⑬
⑤
④
⑥
⑦
⑨
⑤
⑮
⑭
⑭
②
③
⑧
Housing
Pilot Air Bolt
Diaphragm Spring
Housing Plug
Needle Valve
Air Chamber Braket
Mesh Filter
Test key
Diaphragm
Ball-Float
Air Chamber
Lower Discharge¹
Upper Discharge¹
DESCRIPTION
No.
Housing Plate
Housing O-ring
Dicharge Body O-ring
Housing Bolt
Upper Discharge O-ring
Housing Plug Gasket
⑫
⑩
⑪
⑬
⑮
⑫
16
16
17
17
18
18
19
19
M
M
MR
MR
R
R
R
R
R
R
MR
50
1.1
1.2
2.3
130
Volume
(
ℓ
/hr)
Normal/Peak
Application
(
㎥
/hr)
(Compressor)
Weight
(kg)
1~4
4~10
10~16
1~4
4~10
10~16
0~60
0~60
3 / 15
6 / 30
1/2”
3/8”
3/4”
1/2”
Inlet Outlet
Temp.
(
℃
)
Acetrap20N
Acetrap20NC
Technical Specification
Dimensions
The above specifications are subject to change without notice. 2021.06
Acetrap15N
Acetrap15NC
Acetrap15NS
Size
Pressure
(bar)
L
N
H
L
N
H
Model
Spec.
Warranty
We are responsible for product defects within 16 months of delivery or less than 12 months
from the date of installation. In case of occurrence, the period that occurred earlier is applied
to the two periods to prevent defective parts or incorrect production.
We guarantee free replacement of parts for any functional defects that occur. However,
at the customer's negligence Defects caused by this are excluded from the warranty.
Manufacturer and after-sales center : Ace Co., Ltd.
16-17, Chilsan-ro 387beon-gil, Gimhae-City, Korea
Tel : (82) 55 321 3369
* For oil-free applications, add a "C" to the end of the model name, such as
Acetrap15NC.
* Do not use with toxic, flammable and hazardous fluids.
* Option : Internal viewing glasses (Add “S” to the end of the model name,
such as Acetrap15NS)
Trap housing pressure design conditions (not operating conditions) ;
Maximum allowable pressure (bar) : 20
Maximum allowable temperature (°C) : 120
Do not use this product beyond the
specifications. Use of this product is prohibited
hands. Be sure to touch it after wearing gloves, etc.
Standard thread is PF, NPT thread
and other specifications of screws are
available upon request.
in accordance with local regulations. May be limited under
quoted conditions.