background image

Electrical Safety and Power Cord Connection: 

Important Safety Note: 
 

Do not under any circumstances cut or remove the grounding 

prong from the power cord. For safety this appliance must be 
properly grounded at all times.  

The power cord of the Kegerator unit is equipped with a grounding 

wire and plugs to standard grounded wall outlet to minimize the 

possibility of electric shock hazard. 

If the outlet is a standard 2-prong outlet, it must be replaced with the 

properly grounded wall outlet. 

NEVER USE AN ADAPTER PLUG!

 

Have the wall outlet and circuit checked by a qualified electrician to 

make sure the outlet is properly grounded. Check the outlet voltage 

with a voltmeter. If the results are anything less than 100% of the 

required voltage for operation, it must be corrected immediately. 

WARNING: Compressor warranties are voided if the compressor 

fails due to low voltage or power surge

DO NOT USE AN EXTENSION CORD.  

Using any kind of extension 

cord to connect the unit will void the warranty.  The unit must be close 

enough to a wall outlet, so use of an extension cord not needed. 
The unit should always be plugged into its own dedicated circuit with a 

voltage rating that matches the compressor rating. This provides the 

best performance and also prevents overheating power cord which 

could become a fire hazard from overheated wires. 
Never unplug the unit by pulling the power cord.  Always grip the plug 

firmly and pull it out straight from the outlet. 
Repair or replace immediately all power cords that have become fried, 

melted or otherwise damaged. Do not use a power cord that has 

cracks or abrasion damage along its length or at either of its ends. 
When removing the unit away from the wall be careful not to run over 

or damage the power cord. 

NOTE

: Wiring Diagram label is placed on the interior side wall, additional 

copies will be provided by the manufacturer upon request.

Summary of Contents for UDD-24-48-HC

Page 1: ...USER MANUAL Commercial Kegerator Beer Dispenser Models UDD 24 48 HC UDD 24 60 HC UDD 24 72 HC PLEASE READ THE MANUAL THOROUGHLY PRIOR TO EQUIPMENT INSTALLATION OPERATION AND MAINTENANCE...

Page 2: ...ne of the finest commercial refrigeration units made It is manufactured under strict quality controls with only the best quality materials available When properly maintained your cooler will give you...

Page 3: ...TABLE OF CONTENTS SAFETY PRECAUTIONS UNIT INSTALLATION BEER DISPENSING INSTALLATION MAINTENANCE OPERATION STAINLESS STEEL CARE AND CLEANING UNIT MAINTENANCE CONDENSER CLEANING TROUBLE SHOOTING...

Page 4: ...irs or maintenance Always use protective gloves when cleaning the exterior or interior or touching any interior surfaces or components of the equipment Do not touch the cold surfaces inside the refrig...

Page 5: ...should be installed on a flat and level floor Use a leveling device to make sure the unit is level front to back and left to right including interior floor Kegerator unit should be placed and installe...

Page 6: ...BEER DISPENSING INSTALLATION MAINTENANCE...

Page 7: ......

Page 8: ......

Page 9: ...pressor fails due to low voltage or power surge DO NOT USE AN EXTENSION CORD Using any kind of extension cord to connect the unit will void the warranty The unit must be close enough to a wall outlet...

Page 10: ...se in performance uneven temperature through the unit interior For the best performance maintain at least 4 inches of clearance between the contents and the interior air duct fans Use the shelves that...

Page 11: ...l deposits left from food prep or service should be removed as quickly as possible III Chlorides are present in table salt food and water Household and industrial cleaners are the worst type of chlori...

Page 12: ...supplier If present cleaner contains chlorides ask for an alternative Avoid cleaners containing quaternary salts as they can attack stainless steel causing pitting and rusting 4 Water treatment To re...

Page 13: ...lips screwdriver Stiff bristle brush Adjustable wrench When using electrical appliances basic safety precautions should be followed Disconnect power to unit Remove the left side grill panel by removin...

Page 14: ...gaskets are snapped in completely Remove gasket and wash with soap and water Check condition of gasket and replace if necessary Clean the condenser coil Unplug unit and allow coil to defrost Make sure...