Appendix B: Rack mount configuration
118
•
Elevated operating ambient temperature
The maximum operating temperature of the system is 35°C (95°F).
Careful consideration should be given to installing the system in
an environment compatible with the 35°C (95°F) maximum
ambient temperature.
•
Reduced airflow
The amount of airflow required for the safe operation of the
equipment should not be compromised when installing the system
in a rack.
•
Mechanical loading
Exercise care when mounting the system in a rack to avoid any
accidents.
•
Circuit overloading
Appropriate consideration should be given when connecting the
supply circuit to the system to avoid any circuit overload. The
system name plate rating should be used when addressing
concerns about circuit overload.
Rack mount kit
The rack mount kit components and their respective function is listed
on the table below.
Component
Quantity
Usage
Mounting rails
2
Allows the server to slide in and out of the
rackmount for maintenance purposes.
Each mounting rail consists of the
following:
• Fixed outer rail. Attaches to system rack
with M6 x 13 screws.
• Inner rail. Attaches to the sides of the
server with M4 x 5 screws.
• Middle sliding piece has a steel ball
gearing to control server movement
from and into the rackmount.
Summary of Contents for Altos G5450 Series
Page 1: ...Acer Altos G5450 Series User s Guide ...
Page 18: ...xviii ...
Page 19: ...1 System tour ...
Page 32: ...1 System tour 14 System boards Mainboard ...
Page 41: ...2 System setup ...
Page 50: ...2 System setup 32 ...
Page 51: ...3 System upgrade ...
Page 85: ...4 System BIOS ...
Page 86: ...4 System BIOS 68 ...
Page 113: ...5 System troubleshooting ...
Page 124: ...5 System troubleshooting 106 ...
Page 125: ...Appendix A Server management tools ...
Page 133: ...Appendix B Rack mount configuration ...
Page 134: ...This appendix shows you how to set up the Altos G5450 server in a rack mount configuration ...