![background image](http://html.mh-extra.com/html/acer/altos-r700-series/altos-r700-series_service-manual_8209075.webp)
Chapter 3
68
Removing the Power Supply Cage
1.
At the rear of the chassis, remove the two screws that secure the power supply.
2.
At the end of the power supply, remove the screw that attaches the power supply to the standoff
in the chassis floor.
3.
Lift the fan end of the power supply above the chassis standoff and slide it toward the front of the
server. Lift the power supply out of the chassis.