Acer S205F / S200F User’s Manual
20
Caution
Dummy Carriers and Blank Modules MUST be fitted to ALL unused bays, there will be inadequate
drive cooling if any are left open.
Blank I/O Module
If only one RAID I/O moudle is installed a blank module must be fitted
in the unused bay. No bays should be left completely empty.
Ops Panel
(integral part of chassis assembly) Installed in rear Bay 2
Table 2–2
Altos S200F Storage System Configuration
Module
Location
Drive Bays
ALL
drive bays must be fitted with either a drive carrier module or a
dummy carrier, no bays should be left completely empty.
All drive
carrier modules provide SES Management Services.
Power Supply/Cooling
Modules
Two Power Supply/Cooling modules must be fitted. Full power and
cooling redundancy is provided while a faulty module is replaced. Install
the Power Supply/Cooling modules in rear Bays 1 & 5.
Note: Rear bays are numbered from 1 to 5 commencing from the right
hand side)
JBOD I/O Module
Two JBOD I/O modules should be Installed in rear bays 3 and 4. If only
one module is fitted. Install in rear Bay 4
Blank I/O Module
If only one JBOD I/O moudle is installed a blank module must be fitted
in the unused bay. No bays should be left completely empty.
Ops Panel
(integral part of chassis assembly) Installed in rear Bay 2
Table 2–1
Altos S205F Storage System Configuration
Module Location