Acer AR360 F2 specifications 

 

Regulatory Compliant Standards 

EMC 

 FCC (Class A) 

 CE (Class A) 

 CCC 

 BSMI  

Safety 

 MET 

 CB 

 Nemko/GS 

 

Environmental Specifications 

Dimensions 

438.4 (W) x 675.5 (D) x 43.6 (H) mm (17.26 x 26.57 x 1.71 inches)

 

Weight 

Maximum 

25 kg (55.11 lbs.)

 

Minimum (includes a single HDD, CPU and 
RAM, and PSU)

 

18.5 kg (40.78 lbs.)

 

System inlet 
temperature 

Operating 

0° - 40° C (32° - 104° F) 

Non-operating 

-20° - 60° C (-4° - 140° F) 

Relative 
humidity 

Operating 

8 - 90 % 

Non-operating 

5 - 95 % 

Acoustics 

Idle 

 

 

LWAd 

4.7BA 

 

LpAm 

28dBA 

 

Operating 

 

 

LWAd 

4.7BA (max not over 7.0BA) 

 

LpAm 

28dBA 

Power 

Rated Steady 

–state power 

700 W 

 

Maximum Peak Power 

752.1 W  

 

BTU rating 

2567.600 BTU/hr at 100 - 240 VAC 

Summary of Contents for AR360 F2

Page 1: ...ng maximum compute and IO performance With advanced management and reliability features this 1U rack server is optimized for enterprise level operations in departments and branch offices Internal view 1 2 x 700W 80 PLUS Gold level 1 1 redundant hot swappable 2 2 x dual port Intel I350 Ethernet Controllers 3 2 x Intel Xeon E5 2600 family processors 4 N 1 redundant system fans 5 2 x PCIe 3 0 expansi...

Page 2: ...ower HDD activity LAN 2 Power button 3 Up to 8 x 2 5 SATA SAS HDDs Rear View Rear I O 1 2 x 700W 80 PLUS Gold level 1 1 redundant hot swappable 2 PS2 mouse and keyboard ports 3 Management port RJ 45 4 2 x USB ports 5 Serial port 6 Video port 7 4 x Gigabit LAN ports RJ 45 ...

Page 3: ...ctor 2 5 Type SAS SATA SSD with hot plug capability 2 5 Maximum capacity Up to 16 TB SATA HDD 1 TB 2 5 x 16 HDDs Up to 14 4 TB SAS 900 GB 2 5 x 16 HDDs Storage Controllers Intel 606 chipset with SCU 8 x 3 Gb s SATA SAS ports with RAID 0 1 10 support Onboard SAS support for RAID 0 1 10 Optional hardware SAS RAID controller with RAID 0 1 10 5 6 50 60 and BBU support Expansion slots 2 x PCIe 3 0 x16 ...

Page 4: ...ideo port Serial port System ID LED Management port RJ 45 Optical drive 1x Slim type SATA SuperMulti Optical Drive Graphics BMC embedded controller 128 MB shared video memory 16 MB dedicated Chassis Form Factor 1U rack optimized Power Supply 2 x 700 W 80 PLUS Gold level efficient easy swap power supply units 1 1 redundant hot swappable Security HDD mechanical lock Chassis intrusion alert Administr...

Page 5: ...ight Maximum 25 kg 55 11 lbs Minimum includes a single HDD CPU and RAM and PSU 18 5 kg 40 78 lbs System inlet temperature Operating 0 40 C 32 104 F Non operating 20 60 C 4 140 F Relative humidity Operating 8 90 Non operating 5 95 Acoustics Idle LWAd 4 7BA LpAm 28dBA Operating LWAd 4 7BA max not over 7 0BA LpAm 28dBA Power Rated Steady state power 700 W Maximum Peak Power 752 1 W BTU rating 2567 60...

Page 6: ...umber Type Bus width1 Voltage Connector Location Length PCIe x16 1 PCIe Gen3 x16 3 3V x16 Left riser Full height Half length PCIe x16 1 PCIe Gen3 x16 3 3V x16 Left riser Full height Half length NOTE 1 Indicates the number of physical electrical lanes running to a PCIe connector 2 Default bus assignment in decimal Inserting cards with PCI bridges may alter the actual bus assignment number 3 Slots a...

Page 7: ...ay Configuration Utility Installation scripting support RAID OS support Windows Server 2008 Windows Server 2008 R2 Windows Server 2003 Red Hat Enterprise Linux 5 6 SuSE Linux Enterprise Server 10 11 Additional features NCQ Native Command Queuing Onboard LAN specifications Item Description Controller 2 x dual port Intel I350 Ethernet Controllers Network interface 10Base T 100Base TX 1000Base T Comp...

Page 8: ...color while the nearest one is socket 3 P1DIMMA3 P1DIMMB3 P1DIMMC3 P1DIMMD3 P2DIMME3 P2DIMMF3 P2DIMMG3 P2DIMMH3 in black color For all memory modes the socket 1 in each channel needs to be populated first If socket 1 is empty socket 2 and 3 can t be used The higher rank and bigger capacity DIMM is suggested to be installed from slot 1 3 DIMMs per channel configuration is only supported by single r...

Page 9: ...DIMMs per channel NOTE Support depends on 16GB DIMM availability Dual processor configuration guide DIMM Total No of DIMM P1DIMMA1 P1DIMMA2 P1DIMMA3 P1DIMMB1 P1DIMMB2 P1DIMMB3 P1DIMMD3 P1DIMMD2 P1DIMMD1 P1DIMMC3 P1DIMMC2 P1DIMMC1 P2DIMME1 P2DIMME2 P2DIMME3 P2DIMMF1 P2DIMMF2 P2DIMMF3 P2DIMMH3 P2DIMMH2 P2DIMMH1 P2DIMMG3 P2DIMMG2 P2DIMMG1 8 x x x x x x x x 16 x x x x x x x x x x x x x x x x 24 x x x ...

Page 10: ...rt x8 SDDC Lockstep channels must be populated identically Channel A channel B with identical DIMMs and also channel C channel D with identical DIMMs The DIMM type size manufacturer should be the same Same rule is applied to the CPU2 3 DIMM per channel is only supported by single rank and dual rank RDIMM For UDIMM and quad rank RDIMM maximum two DIMMs per channel Rank Sparing mode An unused spare ...

Page 11: ...y quad rank DIMM is used maximum only 2 DIMM per channel can be supported 3 Bit Organization This platform supports x4 and x8 Note It s not recommend to mix DIMM with different bit organization in one system 4 Speed PC3 6400 DDR3 800 PC3 8500 DDR3 1066 PC3 10600 DDR3 1333 PC3 12800 DDR3 1600 ...

Page 12: ...5 Hz Up to 16 MB RAM address space DDC level 2B compliant Serial SPI E2 PROM video BIOS interface up to 64 KB VESA 3 0 compliant 2D Engine Fully GDI compliant Line draw engine with patterning 2D polygons with patterning capabilities BITBLT engine BLTs between host memory and frame memory Color expansion Clipping Transparency and color keying Dithering VGA Engine High performance 32 bit VGA compati...

Page 13: ...Wattage Rating Watts 819 2 791 8 824 2 825 3 823 8 819 4 818 6 Max Rated VA Volt Amp 820 0 820 8 830 0 832 0 833 8 832 6 832 8 Efficiency at Max Rated Output Wattage 86 94 87 41 91 78 91 77 913 81 91 80 91 80 Power Factor 0 999 0 999 0 993 0 992 0 988 0 984 0 983 Leakage Current mA 1 1 1 0 1 0 1 1 1 0 1 0 1 1 Max Inrush Current A peak 17 87 17 95 17 79 18 01 18 03 18 10 18 00 Max Inrush Current Du...

Page 14: ...o simplify system management with embedded BMC system monitoring and alerting event handling remote power control and KVM over IP Smart Console is OS independent and offers virtual media through floppy ODD and removable disk Smart Server Manager v1 2 Offering 24 7 monitoring for system health and performance Delivers proactive event management features including system event logging event handling...

Page 15: ...1333 1066 MHz 95 W E5 2630 15 MB L3 cache 2 3 GHz DDR3 1600 1333 1066 MHz 95 W E5 2620 15 MB L3 cache 2 0 GHz DDR3 1600 1333 1066 MHz 95 W E5 2630L 15 MB L3 cache 2 0 GHz DDR3 1600 1333 1066 MHz 60 W Intel Xeon processor Quad Core E5 2643 10 MB L3 cache 3 3 GHz DDR3 1600 1333 1066 MHz 130 W E5 2609 10 MB L3 cache 2 4 GHz DDR3 1600 1333 1066 MHz 80 W E5 2603 10 MB L3 cache 1 8 GHz DDR3 1600 1333 10...

Page 16: ...del Port number RAID support LSI MegaRAID SAS 9240 4i 4 internal ports 0 1 5 10 LSI MegaRAID SAS 9260 8i 8 internal ports 0 1 5 6 10 50 60 LSI MegaRAID SAS 9260 16i 16 internal ports 0 1 5 6 10 50 60 Battery Backup Unit BBU07 available Battery Backup Unit BBU08 available RAID HBA for Tape Drive Note LTO tape drives require an add on card for external or internal connectivity Model Port number RAID...

Page 17: ...r 2 10Gbps Intel X520 LR1 server adapter 1 10Gbps Note Intel s 10GbE cards vary in terms or their connecter type The X520 DA2 is a copper connector for lengths up to 7M while the X520 SR1 2 is an optical connection for cables up to 550M The X520 LR1 is for even longer cable lengths up to 10kM Fibre Channel HBAs Model Port number Bandwidth Qlogic QLE2560 1 8 Gb s Qlogic QLE2562 2 8 Gb s Tape Backup...

Page 18: ...ormation in this document is subject to change without notice Images shown are only representations of some of the configurations available for this model Availability may vary depending on region 2012 All rights reserved Microsoft and Windows are registered trademarks of Microsoft Corporation Intel the Intel logo Xeon and Xeon Inside are trademarks of Intel Corporation NOTE Extension warranty ser...