Chapter 4
99
The system doesn't resume from
hibernation mode.
See “Save to Disk (S4)” on page 26.
Hard disk connection board
Hard disk drive
System board
The system doesn't resume from standby
mode after opening the LCD.
See “Save to Disk (S4)” on page 26.
LCD cover switch
System board
Battery fuel gauge in Windows doesn’t go
higher than 90%.
Remove battery pack and let it cool for 2 hours.
Refresh battery (continue use battery until power off, then
charge battery).
Battery pack
System board
System hangs intermittently.
Reconnect hard disk/CD-ROM drives.
Hard disk connection board
System board
Peripheral-Related Symptoms
Symptom / Error
Action in Sequence
System configuration does not match the
installed devices.
Enter BIOS Setup Utility to execute “Load Default Settings”,
then reboot system.
Reconnect hard disk/CD-ROM/diskette drives.
External display does not work correctly.
Press Fn+F5, LCD/CRT/Both display switching
System board
USB does not work correctly
System board
Print problems.
Onboard Devices Configuration
Run printer self-test.
Printer driver
Printer cable
Printer
System Board
Serial or parallel port device problems.
Device driver
Device cable
Device
System board
Keyboard/Touchpad-Related Symptoms
Symptom / Error
Action in Sequence
Keyboard (one or more keys) does not
work.
Reconnect the keyboard cable.
Keyboard
System board
Touchpad does not work.
Reconnect touchpad cable.
Touchpad board
System board
Power Management-Related Symptoms
Symptom / Error
Action in Sequence
Summary of Contents for Aspire 7336 Series
Page 6: ...VI ...
Page 12: ...4 Chapter 1 System Block Diagram For Aspire 7736 7736Z 7336 Series ...
Page 13: ...Chapter 1 5 For Aspire 7540 Series ...
Page 120: ...112 Chapter 6 Aspire 7736 7736Z 7336 Series and Aspire 7540 Series Exploded Diagram ...
Page 151: ...Appendix A 143 Model Definition and Configuration Appendix A ...
Page 182: ...174 Appendix B ...
Page 184: ...176 Appendix C ...
Page 187: ...www s manuals com ...