5 System troubleshooting
88
Specific problems and corrective
actions
Listed below are specific problems that may arise during the use of
your server and their possible solutions.
Power indicator does not light
Do the following:
•
Make sure the power supply module is properly installed.
•
Make sure the power cord is connected correctly.
•
Make sure that the wall outlet has power. Test it by plugging in
another device.
•
Make sure the power indicator on the front panel is lit up green.
•
Remove all add-in cards and see if the system boots.
If reboot is successful, install the cards back in one at a time with a
reboot between each addition to determine if one of them is
causing the problem.
•
Make sure that you have properly installed system compliant
memory modules, and that they are populated according to the
system guidelines.
•
Make sure that you have installed system compliant processors,
and that they are populated according to the system guidelines.
HDD activity indicator does not light
Do the following:
•
Make sure the drive is not disabled in the BIOS setup utility.
•
Make sure the drive is compatible.
•
Make sure you have not exceeded the power budget for the
server.
Summary of Contents for AW2000h-AW170h
Page 1: ...AW2000h Series User Guide AW170h F1 AW170hd F1 AW170hq F1 ...
Page 16: ...xvi ...
Page 17: ...1 System tour ...
Page 30: ...1 System tour 14 ...
Page 31: ...2 System setup ...
Page 38: ...2 System setup 22 ...
Page 39: ...3 System upgrades ...
Page 70: ...3 System upgrades 54 ...
Page 71: ...4 System BIOS ...
Page 99: ...5 System troubleshooting ...
Page 109: ...Appendix A Server management tools ...
Page 114: ...Appendix A Server management tools 98 ...
Page 115: ...Appendix B Rack mount configuration ...
Page 126: ...Appendix B Rack mount configuration 110 ...
Page 127: ...Appendix C Acer Smart Console ...
Page 156: ...Appendix C Acer Smart Console 140 ...
Page 160: ...150 ...