3 System upgrade
56
Removing and installing a PCI riser
assembly
Note:
The PCI riser assembly includes an intrusion switch that
engages the system cover. The intrusion switch is provided to
allow server management software to monitor removal of the top
cover from the server.
Caution!
The PCI riser assembly must be installed to maintain
proper airflow inside the server.
This section explains how to access the PCI riser assembly and remove
and install PCI cards.
To remove the PCI riser assembly:
1
Observe the ESD precautions and pre-installation instructions
described on page 39.
2
Remove the CPU air duct. Perform the instructions described in “To
remove the CPU air duct” section on page 45.
3
Diconnect any cables attached to an installed PCI card.
4
Grasp both riser latches with thumb and forefinger, then pull up to
release the riser assembly.
Summary of Contents for Network Device Altos R520
Page 1: ...Acer Altos R520 Series User s Guide...
Page 10: ...x...
Page 11: ...1 System tour...
Page 38: ...1 System tour 28...
Page 39: ...2 System setup...
Page 47: ...3 System upgrade...
Page 99: ...4 BIOS setup...
Page 136: ...4 BIOS setup 126...
Page 137: ...5 Troubleshooting...
Page 158: ...5 Troubleshooting 148...
Page 159: ...Appendix A Acer Altos R520 rack installation guide...
Page 160: ...This appendix shows you how to set up the Acer Altos R520 server in a rack mount configuration...
Page 172: ...Appendix A Acer Altos R520 rack installation guide 162...
Page 173: ...Appendix B RAID configuration...
Page 184: ...174...