3 System upgrade
80
5
Pull up the module to remove it from the connector
(B)
.
6
Observe the post-installation instructions described on page 40.
To install an ARMC/3 module:
Note:
Prior to installing the ARMC/3 module module, you must
remove the server management port cover module cover on the
rear of the server.
1
Observe the ESD precautions and pre-installation instructions
described on page 39.
2
Remove the CPU air duct. Perform the instructions described in “To
remove the CPU air duct” section on page 45.
3
Insert the standoff into the hole in the ARMC/3 module. The
standoff installs on the bottom side of the module
(A)
.