Comprehensive failure management including:
•
Automatic bad sector reassignment
•
Hot-swapping
•
Spare drive operation (supports both global spare and local spare)
•
Background rebuilding (rebuild priority selectable)
•
Verify-after-write supported on normal writes, rebuild writes and/or
RAID initialization writes
•
Works with any operating systems without additional software drivers
•
5.25” drive profile allows easy integration into external subsystem
enclosures directly into the host system’s drive bay
•
Up to five drive channels (optional 3-channel upgrade) for a total of 75
connected drives
•
Supports up to 15 SCSI IDs per channel
•
Up to 8 logical drives, each with independent RAID modules
•
Up to 8 partitions per logical drive
•
Dynamic mapping of LUNs to logical drives. Two or more LUNs can be
mapped to the same logical drive for redundant host operation
•
Performance optimization for Sequential or Random I/O
•
Allows multiple drive failure and concurrent multiple drive rebuild of a
RAID (0+1) logical drive
•
Two or more SCSI channels can be simultaneously set as host interface
for redundant host system operation
•
EDO DRAM supported for enhanced performance
•
Up to 128 Mbytes of intelligent Read-Ahead/Write-Back cache with
optional battery backup
•
Optional battery backup module to protect data in Write-Back cache
when a power failure occurs
•
Front panel LCD and push buttons for configuration and message
display
•
Acer RAID Manager and RS-232 terminal interface for RAID
management
Summary of Contents for RS700
Page 1: ...AcerAltos RS700 Enclosure AcerAltos RS700 Enclosure Installation Guide Installation Guide ...
Page 8: ...viii ...
Page 12: ......
Page 26: ...14 ...
Page 33: ...First RS700 Storage Enclosure Second RS700 Storage Enclosure Host Server HBA ...
Page 39: ...27 SCSI Expander ...
Page 59: ...47 8 Select Form a new cluster to create a cluster 9 Input the name of the Cluster ...
Page 63: ...51 16 Select the node1 pri and click UP to get the highest priority ...
Page 68: ...56 ...