25
2.4.8 P.T.Z configuration
P.T.Z configuration includes two submenus: serial port and advance
2.4.8.1 serial port
Pic 2-34
Serial port
Click
“
Start
”
,
base on P.T.Z support Protocol to set Address, Baud rate,and Protocol.
User can setup all channels with same serial port parameters, please tick off “All”, and
then to do relevant setup. click “Default” button to resort default setting; click “Apply” button
to save the setting; click “Exit” button to exit current interface.
Definitions and descriptions of serial port:
2.4.8.2 Advance configuration
Pic 2-35
Advance
Parameter
Meaning
Address
The address of the PTZ device
Baud rate
Baud rate of the PTZ device. Range form: 110, 300, 600, 1200,
2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400,
460800, 921600.
Protocol
Communication protocol of the PTZ device. Range from:,
PELCOP, PELCOP1, PELCOP5, PELCOD, PELCOD1, HY,
PHILIPS, SAMSUNG SHARP,SONY, SAMSUNG, PANASMIC ,
CONTROLl, etc…