If the BGA rework station alarms caused by any failure, all function buttons will be
locked until after the failure is resolved, then power off and power on, you can use it again.
Widely used temp profile parameters for reference
Leaded temperature profile setting for reference:
Lead free temperature profile setting for reference:
ACHI IR12000 Other cautions:
1.Pow er on the
i nfr ar ed BGA r ew or k stati on
to check w hether b ottom hot ai r
nozzl e ar e w i th col d b l ow i ng . If not, D O N OT touch START b utton to av oi d
b ur n the b ottom heater s.
1st
2nd
3rd
Upper Temp
150
180
220
Upper Rate
3
3
3
Time Constant
100
60
80
Lower Temp
150
180
210
Lower Rate
3
3
3
Time Constant
30
30
30
Infrared Temp
180
0
0
Infrared Rate
3
0
0
Time Constant
300
0
0
1st
2nd
3rd
Upper Temp
180
220
240
Upper Rate
3
3
3
Time Constant
100
80
100
Lower Temp
150
180
210
Lower Rate
3
3
3
Time Constant
100
80
100
Infrared Temp
180
0
0
Infrared Rate
3
0
0
Time Constant
280
0
0