2.D iff er ent BGA r ew or ki ng need di ff er ent tem per atur e p r ofi l e.The m axim um
of each tem per atur e segm ent cannot exce ed 300
.
℃
If i t is l ead f r ee sol deri ng , user s can set temp er atur e pr ofi l e accor di ng to the
BGA sol der b al l sol der i ng tem per atur e.
3.W hen do desol der i ng , adj ust cool i ng f an and v acuum b utton to automatic
status. When the temperature is about to run out, the machine will buzz automatically,
now use the vacuum suction pen to remove away the BGA chip quickly, then move the
PCBA board from the fixture.
4.W hen do sol deri ng , adj ust the cooli ng f an to automatic status and turn off the
vacuum suction system, and the temperature is about to running out, the machine will
buzz to alarm, and the cooling fan begin to cool the BGA and PCB board, and the hot air
nozzles blow cold wind now.M ov e the top heater up to m ake sur e the i nf r ar ed
p l ate i s 3- 5cm aw ay fr om the BGA s urf ace and after g etti ng cooli ng f or 30 to
40 seconds, or the Star t b utton i ndicator off, m ov e the PC B b oar d aw ay f r om
the fi xtur e.
5.Before soldering the BGA, make sure the PCB pads and
BGA solder balls
are 100% ok.
After place the BGA, w e shoul d do cosmetic examine. If they looks not ok, do not do
soldering to avoid damaging the BGA and PCB boards.
6.The BGA rework station surface need to be cleaned often, especially the infrared area.
Because residue on the area will affect the normal heating distribute and reduce the use
life of heating.
Shenzhen Scotle Technology Comp.Ltd
ADD
: Add: 038-068 2F Hand-maken Culture Street, phase III,
Shuiku Road, Bantian,Longgang, Shenzhen, China
Tel
: (86) 755-83692414
Fax
:(86) 755-89378931
Website
:
www.easyBGA.com
www.achibgarework.com
:
easybga@gmail.com
Summary of Contents for IR12000
Page 3: ...3 ...
Page 13: ...13 2 The touch screen shows interface as below you can select your target language ...
Page 14: ...14 3 Choose English turn up below interface ...
Page 15: ...15 4 After input password below interface shows ...
Page 17: ...17 6 Click and Click to run the current selected temperature profile ...