background image

7

4) Camera setup (How to enter into OSD menu)

- OSD (On Screen Display) control

This controller can be used to control speed dome camera,  ptz dome
camera with OSD menu.

Please, refer also to camera OSD menu to avoid conflict in
settings.

- How to enter into OSD Menu

Pressing numeric keypad 1 and MENU button respectively enable
OSD (On Screen Display) Menu to mark on the monitor.

 

The delay time between push 1 button and MENU button is about

2-3 sec.

- The shift of cursor in OSD is as follows.

¬

 Left cursor - Joystick pan left (For speed dome camera only)

-

 Right cursor - Joystick pan right (For speed dome camera only)

®

 Up cursor – Joystick tilt up (For speed dome camera only)

¯

 Down cursor - Joystick tilt down (For speed dome camera only)

°

 Enter F/F button (For speed dome camera, ptz dome camera)

±

 ESC – F/N button (For speed dome camera, ptz dome camera)

²

 Up cursor – Z/I

 

button (For ptz dome camera only)

³

 Down cursor – Z/O button (For ptz dome camera only)

- How to save and quit in OSD.

Keypad “1” + “MENU”
After setup or change parameters, press again numeric keypad 1 and
MENU button respectively enable  OSD(On Screen Display) Menu to
mark on the monitor.

 

The delay time between push 1 button and MENU button is about

2-3 sec.

5) Preset Point

The controller makes to memorise 64 sets of the individual  preset
position for each camera.
The memorised  preset point is available in resetting of power, and it
can be changed.

- Starting the preset mode

SET + Keypad 1-64 + PST
This mode enable pan/tilt and zoom/focus far/near work by joystick.
Thus it can move the point of setting. After put and stop it in place you
want to surveillance, and set it following these orders.
Appoint preset point no.  of the present position with keypad. Operate
with joystick and zoom, focus button, and press the PST button, then it
memorises the number 1  Preset. At this moment, it also memorises
brightness, BLC, WDR, S-BLC. If you want to memorise another
position with  preset point, move to the joystick and repeat. The input
will be ignored, if preset no. Input is out of range between 1-64.

- Movement to a preset point

Appoint preset point number with numeric keypad. Appoint the number
of preset of 1-64 

Ü

 Pressing the PST button automatically enable it to

move to appointed point.
When the error occurs, two times of beep sound.

- Deleting each preset

Press the CLR button for a while (more then 3sec)
Keypad 1-64 

Ü

 PST button 

Ü

 ENT button

Ex) deleting the number 5 of preset:
CLR (more then 3sec) 

Ü

 Keypad 5 

Ü

  PST button 

Ü

 ENT button

- Deleting all preset

Press the CLR button for a while (more then 3sec) 

Ü

 PST button 

Ü

ENT button.

Summary of Contents for AT6SD

Page 1: ...AT6SD KEYBOARD CONTROLLER Instruction manual ref Mi 3146 Please read carefully and completely this manual before install the product and keep for future reference ...

Page 2: ...f Camera 4 Camera Setup How to enter into OSD menu 5 Preset Point 6 Swing 7 Group 8 Tour 9 Spiral Function 10 PTZ trace 11 Camera Remote Reset 12 Brightness Control of LCD 13 Alarm On Off 6 Maintenance and Mending 19 7 Connections 20 8 General Specifications 21 1 Controller 2 Junction box 3 DC Power Supply 4 Camera Control Interface 5 Constitution of Junction box pin 6 Constitution of pin between ...

Page 3: ...wer supply Always handle the connecting cords properly Never damage or modify the connecting cords Never pull on the connecting cord expose them to extreme heat and or place heavy objects on top of them Failure to follow these warnings could result in fire electrical shock or other damage or injury CAUTION Always use the unit indoors The unit should never be used outdoors or in any place where it ...

Page 4: ...nd tour Features Control up to maximum 255 cameras Several keyboards can be used to simultaneous control of a camera Easy operation of pan tilt with the joystick Same effect as 64 fixed surveillance camera by setting a maximum of 64 preset points Pan tilt swing function Group surveillance function select preset points routinely and repeatedly Tour surveillance function repeated practice of many gr...

Page 5: ...ts and AUX1 only for receiver unit GROUP Button This button is used to monitor the preset pionts sequentially TOUR Button This button is used to monitor the groups sequentially SET Button This button is used to start the setting mode of various function Z I Zoom In Z O Zoom Out Button Operate the zoom control of camera AUX Auxiliary Buttons These buttons are used to control of Auto Pan AUX1 and ot...

Page 6: ...monitor can be viewed Downward Tilt When joystick is operated downward it will make the camera move down and the lower part of the color monitor can be viewed Left Pan When joystick is operated to leave it will make the camera move to left and the left part of the color monitor can be viewed Right Pan When joystick is operated to right it will make the camera move to right and the right part of th...

Page 7: ...ut 2 3 sec 5 Preset Point The controller makes to memorise 64 sets of the individual preset position for each camera The memorised preset point is available in resetting of power and it can be changed Starting the preset mode SET Keypad 1 64 PST This mode enable pan tilt and zoom focus far near work by joystick Thus it can move the point of setting After put and stop it in place you want to survei...

Page 8: ... Keypad 1 64 ENT Swing time The standby time dwell time before starting from A or B sec Swing speed The moving speed from A to B 1 sec 64 sec Start and stop of swing Execution 1 Pan 2 Tilt SWING Stop SWING or Joystick 7 Group It is repetitive surveillance function which sequentially switch to multiple of preset points with the speed and standby time designated 64 preset points in maximum can be re...

Page 9: ...e supported only at speed dome camera the fixed pan speed and tilt speed is operated at the same time that can make a spiral function 10 PTZ trace The controller is made to meet to the function in speed dome camera This function makes to memorise P T Z movement for about 120 seconds and play that trace movement Picture 10 1 Picture 10 2 Practising and stop of PTZ trace Keypad 8 MENU ON Practicing ...

Page 10: ...of buzzer When setting Alarm off buzzer and tlickering vanish 6 Maintenance and Mending If the surface of the controller unit becomes dirty turn off the power and wipe the surface with a soft dry cloth CAUTION Never use strong cleaners such as alcohol benzene or paint thinner to clean the surface of the unit They will damage the surface and could cause fire or other accidents Cleaning and inspecti...

Page 11: ...erature 5 C 50 C Working humidity 10 75 Storage humidity 10 95 Dimension 338 L x 180 W x 45 H Weight about 1 2 Kg 2 Junction box Item Specification Power supply In output terminal DC 9V 500mA Adapter In output terminal Modular jack Control I F between camera and controller RS 485 RS 422 Working temperature 0 C 40 C Storage temperature 5 C 55 C Working humidity 10 75 Storage humidity 10 95 Dimensio...

Page 12: ...nput Output Camera Ö Junction box Ö Sub key RS 485 Camera data RS 485 Camera data RS 422 In RS 422 In Camera control 1 GND RS 485 Camera data RS 485 Camera data RS 422 In RS 422 In Camera control 2 GND RS 485 RS 485 RS 485 RS 485 RS 422 In RS 422 In RS 422 In RS 422 In Sub keyboard GND SK RTS RX RTS GND Camera control 1 and 2 compose each separate drive circuit internally 6 Constitution of pin bet...

Page 13: ...tting up Tour Start tour surveillance Stop tour surveillance ž ž MENU 1 MENU F F Joystick F N Start menu mode Mark of OSD Menu OSD Menu enter OSD Menu escape ž ž Function input Operation Function Main Sub 2 MENU ON OFF Set motion detect ON or OFF ž 3 MENU ON OFF Place of detection display ON OFF ž 4 MENU Joystick Z I Z O F F F N Mode of set up zone size displayed Expansion of zone size up down rig...