4.0 FUNCTION SETTINGS (DEFINED BY CUSTOMER)
4.1 Pushbutton Function Setting:
UP/DOWN, NORTH/SOUTH, EAST/WEST,R1/R2, R3/R4 Pushbutton Function Setting
Item
Title
Content
Description
1
Button Function
1. Normal/Normal
2. Toggle/Toggle
3. No/Off
4. Normal/Toggle
5. Dual Motor(1)/Dual Motor(1)
6. Dual Motor(2)/Dual Motor(2)
7. 3 Speed Accel. / 3 Speed Accel.
8. Digital Accel. / Digital Accel.
9. Normal/Dual Motor(1)
10. Normal/Dual Motor(2)
11. Toggle/Dual Motor(1)
12. Toggle/Dual Motor(2)
13. Toggle/3 Speed Accel.
14. Synthesis/Synthesis
NOTE:
500 Series Model 5008
Up/Down Pushbuttons are for full
functions, the rest are for Normal,
Toggle, On, Off only.
Normal:
The relative relay is
"ON"
when the
Pushbutton is pressed and held.
The relative relay is
"OFF"
when the Pushbutton is
released.
Toggle:
Press the Pushbutton and release once for
"ON",
re-press and release for
"OFF"
ON & OFF:
Two relative Pushbuttons are set to
respectively control the same relay. If a Push- button
set as
"ON"
is pressed and released, the
relay remains conductive. At this time, the other
Pushbutton can't change the situation of this relay
except the Pushbutton set as
"OFF".
Dual Motor(1):
When Pushbutton is released from
2nd speed and back to 1 st, the 1st speed relay is
activated again til the Pushbutton is totally released.
Dual Motor(2):
When Pushbutton is released
from 2nd speed and back to 1 st, the 1st speed relay
is not activated but bypassed.
3 Speed Accel.:
Use
"START"
to accelerate to
3 Speed
Digital Accel.:
Use
"START"
to accelerate to 4
Speed
Synthesis:
Three relays used for two dual- speed
motions, the fourth relay works as
independent
"TOGGLE"
ON and OFF function
when two Pushbuttons pressed simultaneously and
again.
2
Acceleration
Delay
0-4.0 seconds
This function is used to set the time interval between
acceleration relays (i.e. conduction delayed time of
acceleration delay. It is suitable for accelerative
operation to prevent the crane from running at a higher
speed to damage the motor.
3
EMS Control
1. Control by EMS
2. Bypass EMS
Control by EMS
means the corresponding relay of
function Pushbutton is controlled by EMS
mushroom or emergency stop signal.
Bypass EMS
means the corresponding relay
of function Pushbutton will not be controlled by
EMS mushroom or emergency stop signal.
4
Interlock
Function
1. Interlock Delay
0-2 seconds
2. Non-Interlocked
Interlock:
If it is dangerous or improper to
operation two motions at the same time, select
"INTERLOCK".
Delay time means the time interval
before next motion is valid.
Non-Interlocked:
If two motions are safe or
irrelevant to operate at the same time, select
"NON-INTERLOCKED".