Remote Control Systems
PAGE: 15
200, 400, and 500 Series
Remotes-0214
2721 NE 4th Ave Pompano FL 33064 | (954) 367-6116
Visit WWW.ACIHOIST.COM for the most current information
Receiver Function Setting
Item
Title
Content
Description
1
Passive Act
1. Relay OFF
2. POWER OFF
Passive Act:
The function of this item is used to
set the reaction of receiver when no command
signal is received from transmitter in certain time
(the default time is 0.5 seconds).
Relay OFF
means the Main Relay is still
"ON"
but
the other relays with the
"NORMAL:'
function are all
de-energized. It is not necessary to re-commence
the procedure of
"POWER-ON"
again to continue
operating.
POWER OFF
means the Main Relay and all of
the other relays with the
"NORMAL:'
and
"Control
by EMS" functions are going to de-energize and
it is essential to re-commence the procedures of
"POWER
ON" again to continue operation.
2
Passive Act Tim-
ing
0.1
-4
seconds
The duration working time of receiver between
passive act is activated and the power or relay is
really OFF.
3
Auto-OFF (RX)
1. None-Execute
2. 10 minutes~4 hours
POWER OFF
Enable:
When Transmit Mode is set for continu-
ous, it will send an EMS signal to
"POWER-OFF"
the receiver if it is set to auto off in a certain time-
frame.
Disable:
Disable the function to send EMS signal
to receiver before the transmitter is off.
4
Remote Setting
1. Enable
2. Disable
Enable:AIIow
the receiver to do ID-Code remote
setting.
Disable:
Not allow ID-Code remote setting on
receiver.