Crane Scales
PAGE: 9
Model HACS
689 SW 7
th
Terrace, Dania Beach, FL 33004 | (954) 367-6116
Visit WWW.ACIHOIST.COM for the most current information
Function
The scale stores a tare weight, and shifts to Net Mode. All subsequent readings are deviations from the tare
value.
The TARE indicator
lights on.
The weight reading turns to “0” (or “0.0” or “0.00”, depending on the resolution).
Condition
The scale must not be in Hold mode. Otherwise, error message
will keep flashing.
The scale must be stable. Otherwise, error message
will flash.
Current weight reading must be greater than 0 (or 0.0 or 0.00, depending on the resolution). Otherwise, error
message
will flash.
Current weight reading must be less than 100% of scale’s Maximum Capacity. Otherwise, error message
will flash.
The scale must be in gross mode. Otherwise, this action will be recognized as Tare Out.
Setting or changing TARE has no effect on
the ZERO setting.
Taring will reduce the apparent overloading range of the
scale. For example, if a 1000kg container is tared and
the scale maximum capacity is 5000kg, the scale will
overload at a new weight of 4009kg (5000 – 1000 +