WARRANTY

The ACI PM Room Series are covered by ACI’s Two (2) Year Limited Warranty, which is located in the front of ACI’S 
SENSORS & TRANSMITTERS CATALOG or can be found on ACI’s web site: www.workaci.com.

W.E.E.E. DIRECTIVE 

At the end of their useful life the packaging and product should be disposed of via a suitable recycling 
centre. Do not dispose of with household waste. Do not burn.

PRODUCT SPECIFICATIONS

16-28VAC/16-35VDC (Reverse Polarity Protection)
4-20 mA: 500 Ohms maximum | 0-10 VDC: 2K Ohms Minimum
0~500μ g/m3
4-20mA(Default), 0-10VDC
N.O. rated 3A @ 30VDC, 3A @250VAC
100μ g/m3
+/-10μg/m3 @ 0~100μg/m3, +/-10% reading @ 
100~500/600µg/m3@25°C/50%RH
1 μg/m3
In continuous service mode, sample time <1s, response time <10s
15 minutes
MTBF more than 3 years in continuous service mode, service life up to 8-10 
years in auto (intermittent)
service mode
Modbus RTU; EIA RS-485
1-247
4800 or 9600
None/Even/Odd
1
8
Screw Terminal Blocks / 16 AWG (1.31 mm2) to 22 AWG (0.33 mm2)
0.45 lbf-in (0.5 Nm) nominal
32 to 122°F (0 to 50°C)
-30 to 70°F (-34 to 21°C)
10 to 95% RH, non-condensing
IP30
ABS Plastic / UL94V-0

Supply Voltage:
Output Load Resistance:
Measurement Range:
Output:
Relay:
Relay Trip Point:
Accuracy: 

Resolution:
Response Time:
Warm Up Time:
Service Life: 

Communication Protocol:
Sensor Addresses:
Supported Baud Rates:
Parity:
Stop Bits:
Databits:
Connections / Wire Size:
Terminal Block Torque Rating:
Operating Temperature Range:
Storage Temperature Range:
Operating Humidity Range:
Enclosure Protection:
Enclosure Material / UL Flammability:

Version: 1.0

I0000941

Summary of Contents for PM2.5-ROOM

Page 1: ...set to Auto Mode IMPORTANT PRECAUTIONS This product uses a laser particulate matter sensor It is strictly prohibited to be disassembled It is dangerous if the human body is exposed to the laser directly If the environment exceeds the measurement range for an extended period it may lead to a decrease of the measurement accuracy The performance of the sensor may be decreased due to excessive dust an...

Page 2: ...ansformer IF THE 24 VDC OR 24VAC POWER IS SHARED WITH DEVICES THAT HAVE COILS SUCH AS RELAYS SOLENOIDS OR OTHER INDUCTORS EACH COIL MUST HAVE AN MOV DC AC TRANSORB TRANSIENT VOLTAGE SUPPRESSOR ACI PART 142583 OR DIODE PLACED ACROSS THE COIL OR INDUCTOR THE CATHODE OR BANDED SIDE OF THE DC TRANSORB OR DIODE CONNECTS TO THE POSITIVE SIDE OF THE POWER SUPPLY WITHOUT THESE SNUBBERS COILS PRODUCE VERY ...

Page 3: ... measuring time to extend the service life of the sensor when the dust concentration changes very slightly Use MODE jumper to choose the mode The factory default mode is AUTO Notes P999 Reset Once entered rST is displayed Press button All factory default settings will be restored P161 1 Point Calibration The current value is displayed Press button to increase an offset Press button to decrease an ...

Page 4: ...uires that the last device in a chain have a termination resistor This is controlled using a jumper in the center and right pins 120 Ω position marked on FIGURE 7 When the jumper is set to 120 Ω a 120 Ω resistance is added in parallel to the data line When the jumper is set to left and center pins disabled the resistance is not added By default the jumper is placed in the disabled position ERROR C...

Page 5: ...Menu selection see above for Menu Adjustments The device that requests information is called the Modbus Master and the devices giving the information are Modbus Slaves The Modbus sensors are slave devices and the number of Data Bits needs to be the same as in the Master device configuration ACI s Modbus RTU sensors utilize 8 data bits during communication exchange Parity default setting is NONE St...

Page 6: ...emarks PM series Product code 9070 PM2 5 Value ug m PM10 Value ug m Default slave address 1 RTU 9600 n 8 1 Write 40016 21845 to reset to factory default setting 0 Off 1 Relay activated Below the set point 2 Relay activated Higher than set point 3 Relay activated in the set range 4 Relay activated outside the set range Relay control parameters set Baud rate 9600 default or 4800 Parity 0 NONE 1 ODD ...

Page 7: ...0 reading 100 500 600µg m3 25 C 50 RH 1 μg m3 In continuous service mode sample time 1s response time 10s 15 minutes MTBF more than 3 years in continuous service mode service life up to 8 10 years in auto intermittent service mode Modbus RTU EIA RS 485 1 247 4800 or 9600 None Even Odd 1 8 ScrewTerminal Blocks 16 AWG 1 31 mm2 to 22 AWG 0 33 mm2 0 45 lbf in 0 5 Nm nominal 32 to 122 F 0 to 50 C 30 to...

Page 8: ...nc 2305 Pleasant View Road Middleton WI 53562 Phone 1 888 967 5224 Website workaci com Page 8 Automation Components Inc 2305 Pleasant View Road Middleton WI 53562 Phone 1 888 967 5224 Website workaci com Version 1 0 I0000941 ...

Reviews: