Page 13 / 26
DTUS066 rev A1 March 21, 2012
V.2
P-GEN
HE10/HE13/HE14/Strip Male Header 2.54mm pitch, 2x5 pins
- Compatible with HE10/HE13/HE14 Female Receptacle
(ex: SAMTEC Series BCS, BSW, ESQ, ESW...)
(ex: ANTELEC Series APC104, FT2...)
Pin
In/
Out
Function
Voltage
Max current
1
Out
LED Ethernet 100 BaseT
active at 3.3V
2 mA
2
Out
1V8 (for feeding the Ethernet
transformer on the TTL
version)
not for power use
-
3
Out
LED Ethernet Link/Activity
active at 0V
2 mA
4
Out
LED WLAN Activity
active at 0V
15 mA
5
Out
LED Diag
active at 3.3V
5 mA
6
In
Reset
active at 3.3V
20 µA
7,9
In
Power +5V
+5V ± 0.25
2A with normal version
2.5A with /3 version
8,10
-
Power GND
0V
WARNING : You must take care of the polarity of the power
supply source. There is no protection on this product.
V.3
P-LED
HE10/HE13/HE14/Strip Male Header 2.54mm pitch, 2x3 pins
- Compatible with HE10/HE13/HE14 Female Receptacle
(ex: SAMTEC Series BCS, BSW, ESQ, ESW...)
(ex: ANTELEC Series APC104, FT2...)
Pin
Function
Voltage
Max current
1
LED Ethernet 1000 BaseT
active at 3.3V
2 mA
2
LED WLAN Status
active at 0V
15 mA
3
LED WLAN Bargraph level 3
good signal
active at 0V
15 mA
4
LED WLAN Bargraph level 2
medium signal
active at 0V
15 mA
5
LED WLAN Bargraph level 4
excellent signal
active at 0V
15 mA
6
LED WLAN Bargraph level 1
poor signal
active at 0V
15 mA
When one WLAN quality bargraph led is on, all the lesser-quality leds
are also on (this is a software feature).