Problem
Possible Cause
Solution
Ozone Generator
light not
illuminated while
system is
operating.
A power surge in the Ozone
Generator may have caused
a blown fuse or there may be
moisture in the ozone
generator module.
Change the fuse in the Aclarus Control
Panel.
If the fuse blows after being reset, refer
to the Maintenance Chapter.
Light is burned out.
Refer to Maintenance Chapter.
Water column on
system is full of
water and water is
going down the
drain
Valve in Mazzei Injector has
failed.
Refer to the Maintenance Chapter for
instructions on performing maintenance
on the Mazzei and pump.
Unusual odour or
smell of ozone
around the system.
The ¼” line venting the gas-
off chamber is leaking or not
vented properly.
1. Make sure ¼” line is vented to
appropriate location and is functioning
properly.
2. Examine the Teflon on the threads of
insert fitting and gas-off chamber to
ensure there is an airtight seal.
3. Check the vent line for any blockages
or debris, and clear as needed.
Ozone is escaping from
ozone generator.
Place system in bypass and disconnect
power.
For Other System Concerns or Possible Problems contact Aclarus or your Aclarus Representative.
NOTE: For specific steps in replacing the valves or servicing the inlets, or any
part of the system contact Aclarus or your installer.
.
Summary of Contents for AOWT-7
Page 9: ...9 System Components...
Page 10: ...10 NOTE System components and tank may not be exactly as shown...
Page 47: ...47 Appendix Component Specification Sheets Pumps Specifications...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50 Flow Switch Specifications...
Page 51: ...51...
Page 52: ...52 Mazzei Specifications...
Page 53: ...53 Gas Off 1 Specifications...